A System Based on Photoplethysmography and Photobiomodulation for Autonomic Nervous System Measurement and Adjustment

A prototype to measure and affect the ANS was proposed, and the functions were feasible. The test results show that stimulating the Neiguan (PC6) acupoint can inhibit the SNS.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors built a prototype that uses a photoplethysmography sensor to measure heart rate variability and a light-emitting diode module to deliver photobiomodulation at two acupoints. They tested two subjects, and report that a 10 Hz pulse stimulation at Neiguan (PC6) increased parasympathetic markers, while 40 Hz at Shenmen (HT7) increased sympathetic markers. The authors state that more experiments are needed to confirm these effects.

Participants
2
Who or what was studied
Two human subjects
Limits stated in the abstract
Only two subjects were tested, and the abstract states that more experiments are needed to confirm the effects across different pulse rates, dosages and acupoints.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Background

The imbalance of the autonomic nervous system (ANS) is common worldwide. Many people have high tension when the sympathetic nervous system is hyperactive or low attention when the parasympathetic nervous system is hyperactive. To improve autonomic imbalance, a feasible and integrated system was proposed to measure and affect the ANS status. (2)

Methods

The proposed system consists of a signal-processing module, an LED stimulation module, a photoplethysmography (PPG) sensor and an LCD display. The heart rate variability (HRV) and ANS status can be analyzed from PPG data. To confirm HRV analysis from PPG data, an electrocardiogram (ECG) device was also used to measure HRV. Additionally, photobiomodulation (PBM) was used to affect the ANS status, and two acupuncture points (Neiguan (PC6) and Shenmen (HT7)) were stimulated with different frequencies (10 Hz and 40 Hz) of PBM. (3)

Results

Two subjects were tested with the developed system. HRV metrics were discussed in the time domain and frequency domain. HRV metrics have a similar change trend on PPG and ECG signals. In addition, the SDNN was increased, and the parasympathetic nervous system (PNS: HF (%)) was enhanced with a 10 Hz pulse rate stimulation at the Neiguan acupoint (PC6). Furthermore, the SDNN was increased, and the sympathetic nervous system (SNS: LF (%)) was enhanced with a 40 Hz pulse rate stimulation at the Shenmen (HT7) acupoint. (4)

Conclusion

A prototype to measure and affect the ANS was proposed, and the functions were feasible. The test results show that stimulating the Neiguan (PC6) acupoint can inhibit the SNS. In contrast, stimulating the Shenmen (HT7) acupoint can activate the SNS. However, more experiments must be conducted to confirm the effect by choosing different pulse rates, dosages and acupoints.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Photobiomodulation, Light-emitting diode. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies