Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Pain & Musculoskeletal

An Evaluation of the Effects of Photobiomodulation Therapy on the Peri-Implant Bone Healing of Implants with Different Surfaces: An In Vivo Study

The PBM therapy modulated the osseointegration process and was evidenced mainly on the machined surface.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors studied rabbits with titanium implants having either a machined or a treated surface, with or without photobiomodulation therapy, measuring stability and removal torque at 21 and 42 days. They report that photobiomodulation was associated with higher stability and removal torque on machined-surface implants at 42 days, and with greater bone coverage in microscopy. The abstract describes this as an in vivo animal study.

Participants
20
Who or what was studied
Twenty rabbits randomly divided into four groups receiving machined or treated-surface implants, with or without photobiomodulation therapy
Limits stated in the abstract
The abstract describes a small animal study in rabbits and does not state the wavelength, dose or treatment parameters of the light therapy.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Background

This study evaluates the effects of photobiomodulation (PBM) therapy on the peri-implant bone healing of implants with a machined surface (MS) and treated surface (TS). (2)

Methods

Topographic characterization of the surfaces (scanning electron microscopy [SEM]- energy dispersive X-ray spectroscopy [EDX]) was performed before and after implant removal. Twenty rabbits were randomly divided into four groups: MS and TS groups (without PBM therapy) and LMS and LTS groups (with PBM therapy). After implant placement, the stability coefficient (ISQ) was measured. In the periods of 21 and 42 days, the ISQ was measured again, followed by biomechanical analysis. (3)

Results

The surfaces of the TS implants showed topographic differences compared with MS implants. The ISQ values of the LMS were statistically significant when compared with those of the MS at 42 days (p < 0.001). The removal torque values of the LMS were statistically significant when compared with those of the MS at 21 days (p = 0.023) and 42 days (p = 0.023). For SEM, in general, the LMS, TS and LTS presented high bone tissue coverage when compared to MS. (4)

Conclusions

The PBM therapy modulated the osseointegration process and was evidenced mainly on the machined surface.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Photobiomodulation, Photobiomodulation therapy. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies

Pain & Musculoskeletal

Effect of 810-nm Diode Laser Photobiomodulation on Pain and Patient-Reported Satisfaction after Initial Fixed Orthodontic Appliance Placement: A Randomized Sham-Controlled Single-Blind Clinical Trial

A two-session 810-nm diode laser PBM protocol reduced pain on day 1 after initial fixed orthodontic appliance placement and was associated with higher patient-reported satisfaction in dietary, psychological, and speech-related domains during the first week.

Study · November 18, 2026 · Li S et al.