Assessment of the onset of analgesia and length of analgesia following the use of PBM with different wavelengths: a clinical study

No discomfort occurred from the LED. Among the light sources utilized, the LED multi-wavelength system demonstrated the largest increase in EPT readings, suggesting its potential as a non-pharmacological alternative for achieving dental analgesia compared to diode lasers.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors compared four light sources (660, 808 and 904 nm diode lasers and a multi-wavelength LED) on electric pulp testing responses in 93 healthy premolar teeth from 26 adults. They report that the LED produced the largest and most sustained increases in pulp test scores and caused no discomfort, while the 904 nm and 808 nm lasers caused some discomfort.

Participants
26
Who or what was studied
26 adults aged 22 to 63 years attending a private dental practice, with 93 healthy unrestored premolar teeth tested
Wavelengths
660, 808, 904, 700, 1100 nm
Limits stated in the abstract
The abstract describes a small clinical study of healthy teeth in one private practice setting, and it does not report a control group or long-term follow-up.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

This clinical study assessed photobiomodulation (PBM) induced analgesic effects of diode lasers and an LED light source on the dental pulp. Baseline responses to electric pulp testing (EPT) were recorded in 93 healthy unrestored premolar teeth in 26 adults (age range 22-63 years) attending a private dental practice. The teeth were irradiated on buccal and lingual aspects of the crown, by placing the tips on the middle third of the crown of the teeth, on separate days for each of 4 different light sources (660, 808, or 904 nm diode lasers, or a novel multi-wavelength LED light source (700-1100 nm)) using comparable parameters (100 mW, 30 s, 6 J). EPT scores were measured after a further 1-, 2-, 5- and 20-min. Discomfort caused by PBM therapy was recorded using the Wong-Baker scale. EPT changes were tracked over time using repeated measures analysis of variance. Baseline EPT scores were very consistent between different days (linear regression r2 0.9422-0.9648). All PBM devices caused a significant elevation in EPT at 5 min, with an earlier onset at 2 mins for 904 nm and LED. The LED was the only light source that elevated scores at 20 min. Across 2-20 min, when ranked by effectiveness, the greatest EPT elevations were seen for LED, followed by 904 nm, then 660 nm and finally 808 nm. Discomfort during PBM was most common with 904 nm, followed by 808 nm. No discomfort occurred from the LED. Among the light sources utilized, the LED multi-wavelength system demonstrated the largest increase in EPT readings, suggesting its potential as a non-pharmacological alternative for achieving dental analgesia compared to diode lasers.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
904 nm, 700-1100 nm, 660 nm, 808 nm
Power
100 mW
Total energy
6 J

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Photobiomodulation, Light-emitting diode, Wavelength. Each links to its definition in the glossary.