AI-generated summary
The authors randomly assigned 45 patients with trigeminal neuralgia to a diode laser, a Nd:YAG laser, or a placebo protocol and measured pain with the BPI-facial scale. All groups improved over time, and the authors report that the diode laser was more effective than the Nd:YAG laser for pain and quality of life.
- Participants
- 45
- Who or what was studied
- Patients with trigeminal neuralgia
- Limits stated in the abstract
- The abstract does not report the specific wavelengths of the lasers or details of the placebo protocol beyond the device being switched off.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
Trigeminal neuralgia (TN) is a disease that causes severe pain that can seriously affect the quality of life. This study aimed to compare the effectiveness of two different low-level laser therapies (LLLT) as alternatives to medical treatment to reduce pain and improve the quality of life in patients with TN.
Methods
A total of 45 patients were randomly divided into 3 groups. In the first group, a new-generation diode laser (GRR laser) was applied at predetermined points in the trigeminal nerve line. In the second group, a low-level neodymium-doped yttrium aluminum garnet (Nd:YAG) laser was applied along the affected nerve line. The placebo group received the same protocol with a Nd:YAG laser without the device switched on. The scores were recorded pre- and post-treatment using the Brief Pain Inventory-Facial (BPI-facial) scale.
Results
A statistically significant difference was found between the pre- and post-treatment values of all four variables in the GRR laser, Nd:YAG laser, and placebo groups. When the post-treatment values were compared, statistically significant differences were found between the groups in pain frequency, pain intensity, and interference in facial-specific activities, but no differences were found in general activities.
Conclusions
Both LLLTs can be considered alternative treatment modalities for TN, but the GRR laser treatment was more effective than the Nd:YAG laser treatment in reducing pain and improving the quality of life in patients with TN.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Placebo-controlled, Low-level laser therapy. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.