Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Oral & Dental

Comparative analysis of osteointegration in photostimulated dental implants: 650-976 nm diode lasers versus growth factors

These findings indicate that PBM and L-PRF can significantly enhance osseointegration and improve dental implant stability in the posterior mandible.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors studied 15 patients missing posterior mandibular teeth, comparing dental implants treated with 650 nm laser, 976 nm laser, or leukocyte plasma-rich fibrin against untreated control sides. They report that implant stability, measured by ISQ, increased after three months, with the largest increase in the 650 nm laser group, and that differences among groups were statistically significant.

Participants
15
Who or what was studied
15 patients lacking posterior mandibular teeth, each receiving two implants in the lower posterior region
Wavelengths
650, 976 nm
Limits stated in the abstract
The abstract describes a small sample of 15 patients and does not report the study design in detail or any further limitations.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

This study aimed to assess the effectiveness of photobiomodulation therapy (PBM) and leukocyte plasma-rich fibrin (L-PRF) in enhancing or accelerating osseointegration by promoting dental implant stability. The study included 15 patients lacking posterior mandibular teeth. Each participant received two implants in the mandibular edentulous area at the lower posterior region. The implants on the right side were categorized into three groups: Group A (650 nm laser), Group B (976 nm laser), and Group C with L-PRF (10 implants each). The left side served as the control. L-PRF was applied at the implant base before placement. Laser irradiation was performed on the buccal and lingual sides of the implants. Osseointegration was assessed using the AnyCheck system from Neo-Biotic Company. The Implant Stability Quotient (ISQ), ranging from 0-100, was measured post-operatively and after three months. There was a significant increase in stability after three months, particularly with 650 nm laser photobiomodulation followed by L-PRF application. The differences in ISQ among the three groups were statistically significant. After three months, implant stability was significantly higher both buccally and lingually in Group A, using powers of 75 mW and 100 mW, respectively, compared to the control (P <0.01). These findings indicate that PBM and L-PRF can significantly enhance osseointegration and improve dental implant stability in the posterior mandible. Patients and clinicians should consider the potential benefits of these interventions in implant dentistry, especially in cases involving the posterior mandible, where stability is crucial for successful implant outcomes.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
650-976 nm, 650 nm, 976 nm
Power
75 mW, 100 mW

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Photobiomodulation, Laser, Photobiomodulation therapy. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies