AI-generated summary
The authors used rat spinal cord slice cultures with a partial transection injury to compare four light wavelengths and three intensities for reducing oxidative stress, measured by 3-nitrotyrosine immunoreactivity. They report that 660 nm was the most effective wavelength, and 860 nm also significantly reduced oxidative stress relative to control at all tested intensities. The study used an ex vivo model, so the findings may not directly transfer to living tissue.
- Who or what was studied
- Rat spinal cord organotypic slice cultures with partial transection injury (ex vivo model)
- Wavelengths
- 450, 510, 660, 860 nm
- Limits stated in the abstract
- The study is ex vivo using spinal cord slice cultures rather than living patients or animals, so direct clinical applicability is not established.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
Red/near-infrared light therapy (R/NIR-LT) has been developed as a treatment for a range of conditions, including injury to the central nervous system (CNS). However, clinical trials have reported variable or sub-optimal outcomes, possibly because there are few optimized treatment protocols for the different target tissues. Moreover, the low absolute, and wavelength dependent, transmission of light by tissues overlying the target site make accurate dosing problematic.
Results
In order to optimize light therapy treatment parameters, we adapted a mouse spinal cord organotypic culture model to the rat, and characterized myelination and oxidative stress following a partial transection injury. The ex vivo model allows a more accurate assessment of the relative effect of different illumination wavelengths (adjusted for equal quantal intensity) on the target tissue. Using this model, we assessed oxidative stress following treatment with four different wavelengths of light: 450 nm (blue); 510 nm (green); 660 nm (red) or 860 nm (infrared) at three different intensities: 1.93 × 10(16) (low); 3.85 × 10(16) (intermediate) and 7.70 × 10(16) (high) photons/cm(2)/s. We demonstrate that the most effective of the tested wavelengths to reduce immunoreactivity of the oxidative stress indicator 3-nitrotyrosine (3NT) was 660 nm. 860 nm also provided beneficial effects at all tested intensities, significantly reducing oxidative stress levels relative to control (p ≤ 0.05).
Conclusions
Our results indicate that R/NIR-LT is an effective antioxidant therapy, and indicate that effective wavelengths and ranges of intensities of treatment can be adapted for a variety of CNS injuries and conditions, depending upon the transmission properties of the tissue to be treated.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 450 nm, 510 nm, 660 nm, 860 nm
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Oxidative stress, Phototherapy, Near-infrared, Wavelength. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.