Comparing the effect of diode laser against acyclovir cream for the treatment of herpes labialis

Treatment with diode laser reduced the length of recovery time and pain severity faster than treatment with acyclovir cream. Key words:Recurrent herpes labial, Acyclovir, Low level laser therapy.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors compared a diode laser at 870 nm with acyclovir 5% cream and a laser-off placebo in 60 patients with recurrent herpes labialis. They report that the laser group had shorter recovery time and pain duration than the acyclovir and placebo groups.

Participants
60
Who or what was studied
Patients with recurrent herpes simplex labialis
Wavelengths
870 nm
Limits stated in the abstract
The abstract does not describe the study's sample size per group beyond 20 each, blinding details beyond single-blind, or follow-up beyond lesion crusting as the end point.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Background

Recently alternative therapies such as the use of diode laser therapy have been introduced for recurrent herpes labial infection. The aim of this study was to evaluate the effectiveness of diode laser for treatment of recurrent herpes labialis.

Material And Methods

This was single-blind randomized clinical trial to evaluate the efficacy of diode laser for the treatment of recurrent herpes labial. In total, 60 patients whit recurrent herpes simplex labialis were selected and randomly divided in to three groups. 20 patients received treatment whit diode laser (at a wavelength of 870 nm, energy density 4.5 j/cm2), 20 patients were treated with acyclovir cream 5%, 20 patients received treatment with laser-off (placebo). The end point was lesions crusting. Data analyzed by Tukey HSD Test and One-way ANOVA (at a significance level of 0.05) in SPSS-20 software.

Results

The mean length of recovery time (day) in the laser, off laser, and acyclovir groups was 2.20±0.41, 4.30±1.03, and 3.4±1.142, respectively. There is a significant difference between three groups in this regard (P<0.0001). The mean duration of pain (day) was 1.35±0.74, 2.65±1.27, and 2.30±0.92 for laser, off laser, and acyclovir groups, respectively (P<0.0001).

Conclusions

Treatment with diode laser reduced the length of recovery time and pain severity faster than treatment with acyclovir cream. Key words:Recurrent herpes labial, Acyclovir, Low level laser therapy.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
870 nm
Energy density (fluence)
4.5 j/cm2

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Laser, Wavelength. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.