AI-generated summary
The authors compared low-level laser irradiation and continuous microwave diathermy on the growth of Gram-positive and Gram-negative bacteria in an in vitro model. They report a significant difference between the groups and conclude that low-level laser therapy appeared effective relative to microwave diathermy for the strains tested, with microwave diathermy showing effects dominant on Gram-negative strains.
- Who or what was studied
- Several bacterial strains (Gram-positive and Gram-negative) in an in vitro model
- Limits stated in the abstract
- The study was conducted in vitro with bacterial strains, and the abstract reports a significant result only for laser irradiation alone under a correction method, with other findings described as effect sizes.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background And Objectives
The aim of this study was to compare the effects of low-level laser therapy and continuous microwave diathermy on the growth of Gram-negative and Gram-positive bacteria and to establish their efficacy as an alternative therapeutic modality.
Materials And Methods
Laser fluence of 13 Joules (J)/cm2, 18 J/cm2 and 30 J/cm2 were used against several bacterial strains. Microwave dosages of 25, 50 and 100 watts (W) were used, respectively.
Results
A significant difference between the three groups was observed using repeated analysis of variance (RANOVA) (F value: 0.74, and p value: 0.001). The Greenhouse-Geisser correction (GG) revealed significant results for laser irradiation alone. However, effect size calculation showed effects with microwave diathermy as well as laser fluence.
Conclusions
Low-level laser therapy appears to be an effective modality of treatment when compared with continuous microwave diathermy on the Gram-negative and the Gram-positive bacterial strains tested. Microwave diathermy revealed large and medium effects on the bacterial cell counts with dominant effects on Gram-negative strains.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Energy density (fluence)
- 18 J/cm2, 30 J/cm2
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Low-level laser therapy, Fluence, Effect size. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.