AI-generated summary
The authors report a randomized feasibility trial of dynamic versus static LED lighting in four rooms of a psychiatric inpatient ward for patients with depression. No participant discontinued because of lighting discomfort, but dropout from treatment was high, mainly from early discharge, and the light sensor system proved unstable. The authors describe the study as preliminary and use it to refine a larger trial.
- Who or what was studied
- Inpatients with unipolar or bipolar depression on a psychiatric inpatient ward
- Limits stated in the abstract
- The abstract describes a small feasibility study with high dropout, lack of endpoint assessments, and an unstable light sensor system, so efficacy cannot be inferred.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
Retrospective studies conducted in psychiatric wards have indicated a shorter duration of stay for depressed inpatients in bright compared to dim daylight-exposed rooms, pointing to a possible antidepressant effect of daylight conditions. Dynamic LED lighting, aiming to mimic daylight conditions, are currently been installed in several hospitals, but their feasibility is poorly investigated.
Methods
To investigate the feasibility of these systems, we developed and installed a LED-lighting system in four rooms in a psychiatric inpatient ward. The system could function statically or dynamically regarding light intensity and colour temperature. The system consisted of (A) a large LED luminaire built into the window jamb mimicking sunlight reflections, (B) two LED light luminaires in the ceiling and (C) a LED reading luminaire. In the static mode, the systems provided constant light from A and B. In the dynamic mode, the system changed light intensity and colour temperature using A, B and C. Patients with unipolar or bipolar depression were randomised to dynamic or static LED lighting for 4 weeks, in addition to standard treatment. Primary outcome was the rate of patients discontinuing the trial due to discomfort from the lighting condition. Secondary outcomes were recruitment and dropout rates, visual comfort, depressive symptoms and suicidal ideation.
Results
No participants discontinued due to discomfort from the LED lighting. Recruitment rate was 39.8%, dropout from treatment rates were 56.3% in the dynamic group and 33.3% in the static group. 78.1% in the dynamic group were satisfied with the lighting compared with 71.8% in the static group. Discomfort from the light (glare) was reported by 11.5% in the dynamic group compared to 5.1% in the static group. Endpoint suicidal scores were 16.8 (10.4) in the dynamic and 16.3 (14.9) in the static group. The lighting system was 100% functional. The light sensor system proved unstable.
Conclusion
Dropout from treatment was high primarily due to early discharge and with a lack of endpoint assessments. The feasibility study has influenced an upcoming large-scale dynamic lighting efficacy trial where we will use a shorter study period of 3 weeks and with more emphasis on endpoint assessments. The lighting was well tolerated in both groups, but some found intensity too low in the evening. Thus, we will use higher intensity blue-enriched light in the morning and higher intensity amber (blue-depleted) light in the evening in the upcoming study. The light sensor system needs to be improved.
Trial Registration
ClinicalTrials.gov: NCT03363529.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Light-emitting diode, Trial registration, Primary outcome, Depression. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.