The authors studied 44 patients who received orthodontic micro-implants in the upper jaw, comparing a group treated with 808 nm laser light against a control group. They report that the laser group showed higher implant stability on the Periotest device at 30 and 60 days, with no significant difference in pain. The study is a split-mouth design with a modest sample, so the findings are limited to these measurements.
- Participants
- 44
- Who or what was studied
- Patients receiving orthodontic micro-implants in the maxilla (14 women, 8 men), split between a laser group (n = 22) and a negative control group (n = 22).
- Wavelengths
- 808 nm
- Limits stated in the abstract
- The abstract reports a modest single-study sample and measures only implant stability and pain, without reporting a long-term clinical outcome.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
To evaluate the effect of photobiomodulation (PBM) on orthodontic micro-implants (n = 44; 14 women, 8 men).
Methods
PBM with 808 nm diode laser was applied immediately, 3, 6, 9, 12, 15, and 30 days post the implantation. Results were assessed within same time frames and additionally after 60 days to check for implants stability using the Periotest device. Patients pain experiences following the first day post-treatment and potential loss of micro-implants after 60 days were recorded. The procedure involved insertion of mini-implants in the maxilla for the laser group (L, n = 22) and negative control group (C, n = 22). Irradiation was carried buccally and palatally with respect to the maxillary ridge (2 points). The energy per point was 4 J (8 J/cm2), total dose was 56 J.
Results
Patients did not report significant differences in terms of pain experiences comparing the L and C groups (p = 0.499). At 30 days post-treatment, higher secondary stability of implants was observed in the laser group (Periotest Test Value, PTV 6.32 ± 3.62), in contrast to the controls (PTV 11.34 ± 5.76) (p = 0.004). At 60 days post-treatment, significantly higher stability was recorded in the laser group (PTV 6.55 ± 4.66) compared with the controls, PTV (10.95 ± 4.77) (p = 0.009).
Conclusions
Application of the 808 nm diode laser increased secondary micro-implant stability.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 808 nm
- Energy density (fluence)
- 8 J/cm2
- Total energy
- 4 J, 56 J