AI-generated summary
The authors compared mechanical debridement alone, diode laser alone, and combined treatment in 39 patients with peri-implantitis over 12 weeks. Clinical plaque and gingival indices improved most in the combined group, while S100A8 levels in peri-implant sulcus fluid did not change significantly between groups or over time. The authors note that S100A8 may not be sensitive in short-term follow-up.
- Participants
- 39
- Who or what was studied
- 39 patients diagnosed with peri-implantitis, divided into three treatment groups
- Limits stated in the abstract
- The abstract does not describe randomization, a control group design, or sample size per group, and the follow-up period is short at 12 weeks.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
The aim of this study was to compare the effectiveness of diode laser and combined treatment protocols, applied in addition to mechanical debridement, in the treatment of peri-implantitis on clinical periodontal parameters and S100A8 levels in peri-implant sulcus fluid (PISF). A total of 39 patients diagnosed with peri-implantitis were divided into three groups based on the treatment protocols used: Mechanical Debridement, Diode Laser, and Combined Treatment. Probing depth, clinical attachment level, modified plaque index, gingival index, and PISF volume measurements were recorded at baseline and at weeks 4 and 12. S100A8 levels in PISF samples were measured by ELISA. During the 12-week follow-up period, statistically significant improvements in clinical parameters were observed in all groups compared with baseline (p < 0.05). In the intergroup comparison, the most significant decrease and statistical superiority in mPI and GI values were observed in the combined treatment group (p < 0.001). Although there was no statistically significant difference among the groups in probing depth and clinical attachment gain, the greatest numerical improvement was observed in the combined group. Despite clinical improvement, no significant change in total S100A8 levels was detected between groups or over time (p > 0.05). The combined use of mechanical debridement and a diode laser in the treatment of peri-implantitis is more effective at reducing clinical signs of inflammation than either method used alone. However, the lack of correlation between S100A8 levels and clinical improvement suggests that this biomarker may not be sensitive in short-term follow-up of treatment.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 940 nm
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Inflammation, Biomarker. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.