Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Oral & Dental

Effect of Diode Laser Photobiomodulation on the Stability of Orthodontic Mini-Implants: A Systematic Review of Randomized Clinical Trials

Current evidence suggests that diode laser photobiomodulation may improve the stability of orthodontic mini-implants.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors conducted a systematic review of five randomized clinical trials assessing diode laser photobiomodulation and orthodontic mini-implant stability. Three studies reported improved stability, while two found no significant difference from controls. The authors note that the evidence is limited and heterogeneous, so definitive clinical recommendations cannot yet be made.

Participants
89
Studies included
5
Who or what was studied
Patients receiving orthodontic mini-implants in five randomized clinical trials (89 participants, 178 mini-implants)
Wavelengths
618, 940 nm
Limits stated in the abstract
The authors state that the small number of trials and substantial variability in PBM protocols and stability assessment methods preclude definitive recommendations.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Background/Objectives

Orthodontic mini-implants have become an essential source of temporary skeletal anchorage because of their versatility, minimal invasiveness, and reduced dependence on patient compliance. However, their clinical success relies on maintaining adequate primary and secondary stability throughout orthodontic treatment. Photobiomodulation (PBM) with diode lasers has been proposed as a non-invasive adjunctive therapy capable of enhancing bone healing and remodeling, thereby improving mini-implant stability. Despite encouraging findings, the available evidence remains limited and heterogeneous. The objective was to systematically evaluate the effect of diode laser photobiomodulation on the stability of orthodontic mini-implants.

Methods

A systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The search was conducted in the PubMed, EBSCO, Scopus, and ScienceDirect databases to identify randomized clinical trials published in the last 10 years. Five randomized controlled trials involving 89 participants and 178 orthodontic mini-implants fulfilled the eligibility criteria. Mini-implant stability was assessed using objective methods, including resonance frequency analysis (ISQ) and Periotest values, while one study also evaluated insertion and removal torque. The methodological quality of the included studies was assessed using the Cochrane Risk of Bias 2 (RoB 2) tool, and the certainty of the evidence was evaluated using the GRADE approach.

Results

Three of the five included studies reported improvements in orthodontic mini-implant stability following diode laser photobiomodulation, whereas two studies found no significant differences compared with the control group. Considerable heterogeneity was identified regarding laser wavelength (618-940 nm), irradiation protocols, energy parameters, timing of force application, and stability assessment methods. Most studies presented a low risk of bias, although some concerns remained regarding allocation concealment and blinding. According to the GRADE assessment, the overall certainty of the evidence was considered moderate, mainly because of inconsistency across studies and methodological heterogeneity.

Conclusions

Current evidence suggests that diode laser photobiomodulation may improve the stability of orthodontic mini-implants. Nevertheless, the small number of randomized clinical trials and the substantial variability in PBM protocols and outcome assessment methods preclude definitive clinical recommendations. Future well-designed randomized controlled trials using standardized irradiation parameters and uniform stability assessment methods are required to establish evidence-based clinical protocols.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
618-940 nm

How to read a review: what to check before relying on this kind of research.

Terms in this paper: Photobiomodulation, Laser, Systematic review, Heterogeneity, Risk of bias, GRADE, Control group, Wavelength. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies

Oral & Dental

Evaluation of the effectiveness of repeated piezocision versus repeated low-level laser therapy in the acceleration of upper canine retraction in terms of dentoalveolar and periodontal changes: A three-arm randomized controlled clinical trial

While both repeated piezocision and LLLT accelerate upper canine retraction during the initial three months without harming periodontal health, piezocision seems to be more effective than LLLT in speed and time reduction.

Study · November 18, 2026 · Alfailany DT et al.