Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Skin & Wound Healing

Effect of low-level laser therapy on healing after sinus floor augmentation using allograft and xenograft bone materials

Low-level laser therapy may improve recovery following sinus lift surgery by reducing postoperative trismus. No significant differences were observed between the grafting materials in terms of bone gain.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors compared allograft and xenograft bone materials in sinus lift surgery, with and without 635 nm low-level laser therapy, in 20 randomly allocated patients. They report that laser therapy significantly reduced postoperative trismus and was associated with increased facial swelling, with no significant pain differences. Allografts showed greater homogeneity and xenografts higher radiographic density at 135 days.

Participants
20
Who or what was studied
Twenty patients undergoing lateral sinus lift before implant treatment, randomly allocated to allograft or xenograft groups, with a subset receiving adjunctive laser therapy.
Wavelengths
635 nm
Limits stated in the abstract
The abstract describes a very small sample of 20 patients split into subgroups of about 5, so the findings are of limited statistical strength.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Background

In cases of alveolar bone atrophy prior to implant treatment, sinus floor elevation remains the treatment of choice. During a sinus lift procedure, a stabilizing grafting material is required. Among the many available options, xenografts and allografts are widely used. Owing to their different properties, they can be applied in various clinical settings. Low-level laser therapy (LLLT) is an increasingly popular adjunctive tool in regenerative dentistry. Its beneficial effects on the healing process are well established. However, its ability to influence bone healing following sinus floor elevation remains insufficiently investigated.

Objectives

The primary objective was to compare 2 bone grafts of different origins (allograft and xenograft) used in sinus lift procedures. The secondary objective was to evaluate the influence of LLLT on postoperative recovery in terms of pain, trismus, and soft tissue response.

Material And Methods

Twenty patients were randomly allocated to 2 groups. A xenograft was used in half of the patients, whereas an allograft was used in the remaining patients. In each group, 5 patients were randomly selected to receive adjunctive LLLT using a diode laser with a wavelength of 635 nm and an energy density of 6 J/cm2. All patients underwent clinical and radiological examinations before surgery. Subsequently, a standard lateral sinus lift procedure was performed. Follow-up visits were conducted on postoperative days 3 and 7, during which pain, trismus, and swelling were assessed. After 135 days, cone-beam computed tomography (CBCT) and clinical examinations were performed to evaluate bone gain, density, and homogeneity.

Results

Low-level laser therapy significantly reduced trismus. Trismus was also less pronounced in male patients. Low-level laser therapy was associated with increased facial swelling. Pain levels were low, with no significant differences between the study groups. After 135 days, allografts demonstrated greater homogeneity, whereas xenografts exhibited higher radiographic density.

Conclusions

Low-level laser therapy may improve recovery following sinus lift surgery by reducing postoperative trismus. No significant differences were observed between the grafting materials in terms of bone gain. However, differences in radiodensity suggest distinct resorption patterns, with xenografts exhibiting higher density values after 135 days.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
635 nm
Energy density (fluence)
6 J/cm2

How to read a trial: what to check before relying on this kind of research.

Terms in this paper: Low-level laser therapy, Laser, Wavelength. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies

Skin & Wound Healing

Technological Advances in Wound Treatment of Exotic Pets

Although most research about the use of technological advances for wound healing was performed in laboratory animals but oriented to human medicine, recent technological advances allowed its application not only to small animals but also to exotic pets.

Review · September 1, 2019 · Sabater González M et al.