Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Pain & Musculoskeletal

Effect of ozone and diode laser (635 nm) in reducing orthodontic pain in the maxillary arch-a randomized clinical controlled trial

There were no differences in pain perception between patients with crowded teeth and non-crowded teeth in each group (G1, p = 0.66, G2, p = 0.86, G3, p = 0.24).

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors randomized 76 orthodontic patients to a 635-nm diode laser, ozone therapy, or a control group after fixed appliance placement and tracked pain over five days. They report lower pain scores in the laser group than in controls, with no significant difference for ozone and no effect of teeth crowding or spacing on pain.

Participants
76
Who or what was studied
Orthodontic patients receiving fixed appliances in the maxillary arch (55 women and 21 men, mean age 35.1 years)
Wavelengths
635 nm
Limits stated in the abstract
Single-session treatment with pain tracked only over the first five days; the abstract does not describe blinding or long-term outcomes.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

The effect of ozone, diode laser irradiation, and presence of teeth crowding/spacing on pain perception in orthodontic patient was tested. Overall, 76 patients [55 women and 21 men; age 35.1(6.4) years] who met the inclusion criteria participated in the study. Immediately after fixed orthodontic appliance placement, the patients were exposed to a pain relief treatment (one single session) using either 635-nm diode laser (SmartM, Lasotronix, Warsaw, Poland) or ozone therapy (OzoneDTA, Apoza, New Taipei City, Taiwan) by placing the handpieces in the area of each teeth apex and interdental papillae, from the maxillary right first molar to the maxillary left first molar. Subjects were divided into three groups: control group (G1, n = 26), ozone (G2, n = 26, exposed to ozone therapy, generator probe type 3, working time per point 5 s, 23 points, application time 1 min and 55 s), and laser group (G3, n = 25, exposed to continuous mode diode laser, 400 mW, handpiece diameter 8 mm, spot area 0.5024 cm2, power density per second 1.59 W/cm2, dose 2 J per point, time: 5 s per point, 23 points, total energy per session 46 J, application time 1 min and 55 s). The level of teeth crowding was assessed using the Lundstrom indicator. The patients received a questionnaire for pain assessment (the Numeric Rating Scale, NRS-11, grade level 0-10) and recorded at 7 time points (1 h, 6 h, and 1, 2, 3, 4, and 5 days ) after the fixed orthodontic appliance placement. The mean pain values for the diode laser, ozone, and control group were 3.6 (1.31) (95% CI, 2.95-4.25), 5.25 (3.37) (95% CI, 3.52-6.98), and 5.75 (2.40) (95% CI, 4.69-6.81), respectively. We observed lower pain values in the diode laser group compared to the control group (p = 0.0237). The use of ozone in this study did not result in significant pain reduction in comparison to control (p = 0.8040) and laser groups (p = 0.1029). There were no differences in pain perception between patients with crowded teeth and non-crowded teeth in each group (G1, p = 0.66, G2, p = 0.86, G3, p = 0.24). The use of 635-nm diode laser led to decreased pain perception; however, ozone and presence of teeth crowding/spacing did not affect the pain perception in orthodontic patients during the first 5 days after the fixed orthodontic appliance placement.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
635 nm
Power
400 mW
Total energy
2 J, 46 J

How to read a trial: what to check before relying on this kind of research.

Terms in this paper: Laser, Control group, Light-emitting diode, GRADE, Dose. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies