AI-generated summary
The authors studied 810 nm diode laser treatment of cervical dentine hypersensitivity in five patients with 14 teeth, comparing 30-second and one-minute exposures. They report significant pain reduction on a visual analogue scale after 15 minutes, with pain fading by one week in the 30-second group and disappearing in the one-minute group. The study was small and the abstract does not describe a control group.
- Participants
- 5
- Who or what was studied
- Five patients with at least two sensitive teeth, 14 teeth in total, with cervical dentine hypersensitivity
- Wavelengths
- 810 nm
- Limits stated in the abstract
- The abstract reports a very small sample of five patients and 14 teeth, with no control group described.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
Dentine hypersensitivity is a common clinical finding with a wide variation in prevalence values. The aim of this study was to evaluate the use of diode laser (810 nm) in the treatment of cervical dentine hypersensitivity.
Methods
Five patients, with at least two sensitive teeth were selected. A total of 14 teeth were included in this trial. By using Visual Analogous Scale the pain of dentine hyper sensitivity was detected and the pre- treatment readings were recorded. The Diode laser (810 nm), was irradiated on (non contact) mode at the cervical region. The samples were divided into two groups according to exposure duration: For Group 1 exposure duration was 30 seconds and for group 2 exposure duration was one minute. The efficiency of the treatment was assessed at two examination period :15 minutes after first application and 7 days after first application, the degree of sensitivity was determined by using Visual Analogous Scale.
Results
The results show significant reduction of pain after 15 minutes of laser application in the group with 30 seconds exposure duration (P = .001), and the pain completely fade away after one week in the same group, while in the group with 1 minute exposure duration the pain completely disappeared (visual analogous scale = (0)) after 15 minutes and one week of laser application (P = 0.001).
Conclusion
The study concluded that application of diode laser (810 nm) was effective for the reduction of dentine hypersensitivity.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 810 nm
How to read a trial: what to check before relying on this kind of research.
Terms in this paper: Laser. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.