AI-generated summary
The authors randomized 41 patients, using a split-mouth design, to compare diode laser treatment at 810 nm with orthodontic traction alone for moving maxillary canines. The laser side closed space in a mean of 84.35 days versus 97.49 days on the control side, and reported lower pain scores at 3, 7 and 14 days. The abstract describes these results as a single-trial finding with no long-term follow-up reported.
- Participants
- 41
- Who or what was studied
- 41 orthodontic patients (21 males, 20 females, mean age 13.4 years) with 82 maxillary canines needing distalization after first premolar extraction
- Wavelengths
- 810 nm
- Limits stated in the abstract
- The abstract does not describe long-term outcomes or blinding, and it reports only a single trial.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
The present study evaluated the effects of low-level laser therapy (LLLT) by means of a diode laser in accelerating orthodontic tooth movement (OTM). After extraction of the first upper premolars for orthodontic purpose, 82 maxillary canines which needed distalization were analyzed in 41 enrolled patients (21 males, 20 females, mean age 13.4 ± 2.1 years). On all experimental sites, an orthodontic force of 50/N was applied by a nickel-titanium (NiTi) closed coil spring (G&H, Franklin, IN, USA) in order to obtain the space closure. Using a split mouth randomized design, the test side was treated using a diode laser (Wiser Laser Doctor Smile, Brendola, Italy) operating at 810 nm wavelength in continuous wave mode at both the buccal and palatal side on three points/side (distal, medial and mesial) (1 W output power, continuous wave of 66.7 J/cm2, energy density of 8 J) at baseline and at 3, 7, and 14 days and every 15 days until the space closed. On the control side, the opposite selected canine was treated only using orthodontic traction. The primary outcome chosen was the overall time needed to complete the levelling and closing space, measured on a study cast. The secondary outcome chosen was the evaluation of pain levels related to tooth traction, using a Visual Analogue Scale (VAS), recorded at 3, 7, and 14 days after treatments. The mean space closures of the maxillary canines were comparable between groups [Test, 4.56 mm (95% CI 3.9-4.8); Control, 4.49 mm (95% CI 3.8-4.7), p = 0.456]. The laser group yielded less mean time [84.35 ± 12.34 days (95% CI 79.3-86)] to accomplish space closure compared to the control group [97.49 ± 11.44 days (91.7-102.3)] (p < 0.001). The test side showed a significant reduction in the average range of dental pain at 3 [Test, 5.41 (95% CI 5.1-5.6); Control, 7.23 (95% CI 6.9-7.6), p < 0.001], 7 [Test, 4.12 (95% CI 3.8-4.7); Control, 5.79 (95% CI 5.4-5.8), p < 0.001], and at 14 days [Test, 2.31 (95% CI 1.8-2.3); Control, 3.84 (95% CI 3.3-4.2), p < 0.001] after treatment (p < 0.001). This study demonstrates that the use of LLLT therapy was effective in accelerating tooth movement and reducing pain levels related to OTM.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 810 nm
- Energy density (fluence)
- 66.7 J/cm2
- Power
- 1 W
- Total energy
- 8 J
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Low-level laser therapy, Visual analogue scale, Primary outcome, Control group, Wavelength. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.