The authors conducted a systematic review and meta-analysis of 16 randomized controlled trials with 322 participants comparing physical methods with standard orthodontic care for upper canine retraction. They report that low-level laser therapy and mechanical vibration were associated with moderately faster retraction, with no adverse effects detected on secondary outcomes. The authors note variability in protocols and limited long-term data.
- Participants
- 322
- Studies included
- 16
- Who or what was studied
- Fixed-appliance orthodontic patients undergoing maxillary canine retraction
- Limits stated in the abstract
- The abstract notes variability in protocols, heterogeneity in the low-level laser results, limited evidence for electromagnetic fields, and limited long-term data.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Orthodontic treatments for maxillary canine retraction often extend over long durations, affecting patient comfort and compliance and leading to growing interest in using physical modalities such as low-level laser therapy (LLLT), mechanical vibration, and electromagnetic fields to accelerate tooth movement. This study systematically evaluates and compares the effectiveness of these physical methods in increasing the rate of upper canine retraction in fixed-appliance orthodontic patients. A comprehensive electronic search of six databases was conducted through July 5, 2025, to identify randomized controlled trials (RCTs) evaluating LLLT, mechanical vibration, or electromagnetic interventions for maxillary canine retraction. Eligible studies compared these modalities with standard orthodontic controls and reported the rate of upper canine retraction (mm/month) as the primary outcome, alongside secondary outcomes including canine angulation, rotation, anchorage loss, and root resorption. Risk of bias was assessed using the Cochrane RoB2 tool, and meta-analyses were performed to calculate mean differences (MDs), p-values, and heterogeneity (I²). Sixteen RCTs with 322 participants were included, revealing that LLLT significantly increased the retraction rate (MD = 0.43 mm/month, p = 0.007; I² = 97%), which, after sensitivity analysis, became MD = 0.26 mm/month (I² = 48%). Mechanical vibration also significantly increased retraction (MD = 0.36 mm/month, p < 0.00001), with no heterogeneity (I² = 0%). Evidence for electromagnetic fields was limited but still positive. For secondary outcomes, no significant adverse effects were noted for angulation, rotation, anchorage, or root integrity, although one study reported minimal, nonsignificant root resorption. In conclusion, physical modalities - particularly LLLT and mechanical vibration - can moderately accelerate upper canine retraction without detectable adverse effects. However, due to variability in protocols and limited long-term data, further high-quality RCTs with standardized methodologies are warranted before routine clinical application.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
How to read a review: what to check before relying on this kind of research.
Terms in this paper: Retraction, Low-level laser therapy, Systematic review, Meta-analysis, Heterogeneity, Primary outcome, Risk of bias, Laser. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.