Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Devices & Dosimetry

Effects of low-level laser therapy on the modulation of tissue temperature and hyperalgesia following a partial Achilles tendon injury in rats

Thus, a significant group-versus-time interaction was found for tissue temperature (F = 4.097, p = 0.001) and hyperalgesia (F = 106.605, p < 0.001), with a greater reduction in theses outcomes in the group that received LLLT at a dose of 2.1 J evaluated 48 hours after the injury.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

In this study of rats with a partial Achilles tendon injury, the authors compared a control group with groups given low-level laser therapy at 1.4 J or 2.1 J (808 nm). They report that the 2.1 J group showed a greater reduction in tissue temperature and hyperalgesia at 48 hours after injury. The authors note this was an animal study.

Participants
45
Who or what was studied
Rats with a partial injury to the Achilles tendon
Wavelengths
808 nm
Limits stated in the abstract
This is an animal study, and the abstract does not describe a limitation beyond its design.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

The full abstract is not shown here because it is protected by the publisher’s copyright. Read it on tandfonline.com.

Record from PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
808 nm
Power
50 mW
Total energy
1.4 J, 2.1 J

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Low-level laser therapy, Laser, Dose, Light-emitting diode, Control group, Wavelength. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies

Devices & Dosimetry

Effect of light-emitting diode photobiomodulation on rat liver metabolomics after streptozotocin-induced diabetes - an evidence from nuclear magnetic resonance spectroscopy

Glucose and glycogen signals were less intense in the diabetic liver treated with PBM, while a strong acetate signal was intensified. In conclusion, glucose and glycogen signals were attenuated by PBM, and acetate signals were intensified in diabetic livers.

Study · August 22, 2025 · Tatmatsu-Rocha JC et al.