AI-generated summary
The authors conducted a randomized, double-blind, split-mouth study of 31 adults comparing three 980 nm laser regimens with a placebo for pain after elastic separator placement. At 24 hours, pain scores were significantly different between laser-treated and placebo quadrants, both at rest and during chewing. The authors describe the findings as exploratory and suggest a single laser application might reduce pain.
- Participants
- 31
- Who or what was studied
- Adults aged 19 to 32 years receiving fixed orthodontic appliances who had elastic separators placed on first permanent molars
- Wavelengths
- 980 nm
- Limits stated in the abstract
- The authors describe their findings as exploratory in nature.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
Effective pain management is crucial during orthodontic treatments with fixed appliances, to ensure adequate patient compliance and to avoid treatment discontinuation. Photobiomodulation approaches, including Low Level Laser Therapy (LLLT) has received substantial attention, due to its potential as an effective, non-pharmacological analgesic modality, however, evidence pertaining to its efficacy is controversial. Our present study aims to evaluate the efficacy of LLLT vs. placebo, following placement of orthodontic elastic separators (ESs) in adult patients treated with fixed orthodontic appliances.
Methods
A randomized, double-blind, split-mouth study was carried out, where n = 31 volunteers (18 male and 13 female; aged between 19 and 32 years) were enrolled. ESs were placed at the mesial and distal surfaces of the first permanent molars in both quadrants of lower, as well as upper jaws. Based on the assigned intervention, the four quadrants were divided as follows: three quadrants received LLLT treatment-using a 980 nm wavelength GaAlAs diode laser, with 0.1-0.2 W-according to three treatment regimes, i.e., regime 1 (R1): 6 J, continuous mode, R2: 12 J, continuous mode, and R3: 6 J, pulsed mode; while placebo treatment (P) was applied in the fourth quadrant. A questionnaire with a visual analogue scale (VAS; 0-100) was used for pain assessment (spontaneous pain and pain on mastication), scored directly after separation and after 6, 24, 48 and 72 h of both laser and placebo treatment application.
Results
After the 24 h mark, significant differences were detected between the pain readings of LLLT-treated and placebo quadrants, both in resting position and during mastication (p < 0.05); pain readings were highest for R2, P, while lowest for R3 quadrants in resting position, and at R1 during mastication, respectively.
Conclusions
Although findings of our study are exploratory in nature, they suggest that a single application of LLLT might be effective in reducing pain caused by ES placement, especially in the vulnerable 24 h following separation.
Trial Registration
clinicaltrials.gov ID NCT07456709 (date of
Registration
2 March 2026, retrospectively registered).
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 980 nm
- Power
- 0.2 W
- Total energy
- 6 J, 12 J
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Low-level laser therapy, Laser, Placebo-controlled, Visual analogue scale, Photobiomodulation, Trial registration, Wavelength. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.