The authors tested a transvaginal near-infrared laser device in one anesthetized ewe, measuring light irradiance inside the levator ani muscle and bladder. They report that at 5 W, irradiance reached these deeper tissues, while 0.5 W did not, and suggest higher power settings may be needed for deep pelvic targets.
- Who or what was studied
- One anesthetized adult Suffolk/Dorset ewe (animal model)
- Limits stated in the abstract
- The study used a single animal and measured irradiance only, without any clinical outcomes in humans.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Photobiomodulation therapy (PBMT) is an effective means of treating muscle spasm and pain. A novel near-infrared laser system has been commercialized for the treatment of myofascial pelvic pain in women (SoLá Therapy, UroShape, LLC). This study was undertaken to determine if this device is capable of delivering therapeutic levels of irradiance to the pelvic muscles and to identify the surface irradiance required to achieve this goal. This novel class IV near-infrared laser and transvaginal applicator were used to deliver near-infrared light energy through the vaginal mucosa of an adult Suffolk/Dorset Ewe. Irradiance was measured on the surface of the levator ani muscle, inside the levator ani muscle, and inside the bladder. Measurements were taken at powers of 5 W and 0.5 W. 3.0% of vaginal surface irradiance was measured inside of the levator ani muscle. 4.4% of vaginal surface irradiance was measured inside the bladder. At 5 W, the novel laser system provided a surface irradiance of 738 mW/cm2. At 0.5 W, the system provided a surface irradiance of 74 mW/cm2. A novel class IV near-infrared laser and transvaginal applicator delivered therapeutic irradiance to the levator ani muscle and bladder of an anesthetized ewe at a power setting of 5 W. A power setting of 0.5 W failed to deliver therapeutic energy into either the levator ani muscle or bladder. Clinical applications targeting deeper tissues such as the pelvic muscles and or bladder should consider power settings that exceed 0.5 W and or irradiance of ≥ 75 mW/cm2.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Power density (irradiance)
- 738 mW/cm2, 74 mW/cm2, 75 mW/cm2
- Power
- 5 W, 0.5 W
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Irradiance, Near-infrared, Laser, Photobiomodulation therapy, Photobiomodulation. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.