AI-generated summary
In this rat study, the authors compared two diode laser doses (980 nm, 72 J and 54 J) applied around maxillary incisors under orthodontic force with an untreated control group. The authors report that the 72 J dose increased osteoclast activity relative to control, while the 54 J dose was concluded to accelerate tooth movement.
- Participants
- 30
- Who or what was studied
- Thirty Wistar albino rats (Rattus norvegicus) divided into three groups of 10, two laser groups and one control
- Wavelengths
- 980 nm
- Limits stated in the abstract
- This is an animal study with a small sample, and the abstract does not report the statistical methods or the magnitude of the tooth movement effect.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Purpose
To evaluate the effect of diode laser use on experimental orthodontic tooth movements.
Methods
Thirty Rattus norvegicus albinus Wistar were divided into three equal groups (n = 10), two experimentals and one control. Applying 20 g orthodontic force were attached to the maxillary incisors of the rats in all groups. Low dose laser was applied to the surrounding tissues of the maxillary incisors of the rats in the experimental groups. Two exposure times for laser irradiation were used for seven days: t = 12 min (energy dose = 72 J) and t = 9 min (energy dose = 54 J) by a 0.1 W DEKA brand diode laser with wavelength of 980 nm.
Results
Osteoclastic activation increased in the 72 J group when compared to control group and decreased in comparison to the 54 J group. Osteoblastic activation was decreased in the 72 J group when compared to the control group and increased in comparison to the 54 J group.
Conclusions
Applying 54 J laser energy has been found effective to accelerate the orthodontic tooth movement.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 980 nm
- Power
- 0.1 W
- Total energy
- 72 J, 54 J
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Dose, Control group, Wavelength. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.