Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Devices & Dosimetry

FUNCTIONAL AND CELLULAR EVALUATION OF THE LIVER AFTER LOW-POWER LASER STIMULATION DURING SURGERY

Low-power laser stimulation did not cause loss of liver function or mutagenic damage.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors studied whether low-power laser stimulation applied to the remaining liver during surgery after partial hepatectomy in 15 rats could cause functional or mutagenic damage. They report that liver function tests and the micronucleus test showed no significant differences between groups, and that the laser did not cause loss of liver function or mutagenic damage. The study was conducted in rats with a small sample size.

Participants
15
Who or what was studied
Fifteen adult male Wistar rats that underwent 70% partial hepatectomy
Wavelengths
650 nm
Limits stated in the abstract
The study used a small number of rats divided into four groups, and it was an animal study rather than one in humans.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Background

Partial hepatectomy is a surgical intervention of the liver that can trigger its regenerative process, where the residual lobes deflagrate a compensatory hyperplasia, causing its restoration almost to the original volume. Nevertheless, depending on the extent of liver damage its regeneration might be impaired. The low-power laser has been studied with beneficial results.

Aim

To investigate the possible functional and mutagenic damage arising from the use of low-power laser used in liver regeneration after partial hepatectomy.

Methods

Fifteen male adult Wistar rats were hepatectomizated in 70% and laser irradiated or not with dose of 70 J/cm2, 650 nm, 100 mW, directly on the remaining liver, during the perioperative period. These animals were divided into four groups: G1 (control, 7 days); G2 (laser, 7 days); G3 (control, 14 days); G4 (laser, 14 days). Were analyzed the liver weight; number of hepatocytes; deposition of collagen fibers; liver function tests: serum alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, gamma glutamyl transferase, bilirubin and micronucleus test in peripheral blood erythrocyte.

Results

The liver weight was greater in G3 and G4 (p=0.001 and p=0.002) compared to other groups. The deposition of collagen fibers in G1 was statistically higher than the other groups (p=0.01). In tests of liver function and micronucleus test was not found significant differences between the studied groups.

Conclusion

Low-power laser stimulation did not cause loss of liver function or mutagenic damage.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
650 nm
Energy density (fluence)
70 J/cm2
Power
100 mW

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Laser, Collagen, Dose. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies