AI-generated summary
The authors compared how deeply 405 nm and 808 nm continuous wave lasers, and an 808 nm pulsed laser at low and high pulse frequencies, penetrated beef and chicken tissue samples of increasing thickness. They report that the 808 nm continuous wave laser penetrated about 2.3 to 2.4 times deeper than the 405 nm laser, and that higher pulse frequency was associated with greater penetration depth. The study used tissue samples rather than living patients.
- Who or what was studied
- Beef and chicken tissue samples; no human participants are described in the abstract.
- Wavelengths
- 405, 808 nm
- Limits stated in the abstract
- The abstract describes only ex vivo meat tissue samples, so penetration results may not translate directly to living human tissue.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
The clinical efficiency of laser treatments is limited by the low penetration of visible light used in certain procedures like photodynamic therapy (PDT). Second Harmonic Generation (SHG) PDT is an innovative technique to overcome this limitation that enables the use of Near Infrared (NIR) light instead of visible light. NIR frequency bands present an optical window for deeper penetration into biological tissue. In this research, we compare the penetration depths of 405 and 808 nm continuous wave (CW) lasers and 808 nm pulsed wave (PW) laser in two different modes (high and low frequency).
Methods
Increasing thicknesses of beef and chicken tissue samples were irradiated under CW and PW lasers to determine penetration depths.
Results
The 808 nm CW laser penetrates 2.3 and 2.4 times deeper than the 405 nm CW laser in beef and chicken samples, respectively. 808 nm PW (pulse frequency-500 Hz) penetrates deeper than CW laser at the same wavelength. Further, increasing the pulse frequency achieves higher penetration depths. High frequency 808 nm PW (pulse frequency-71.4 MHz) penetrates 7.4- and 6.0-times deeper than 405 nm CW laser in chicken and beef, respectively.
Conclusions
The results demonstrate the higher penetration depths of high frequency PW laser compared to low frequency PW laser, CW laser of the same wavelength and CW laser with half the wavelength. The results indicate that integrating SHG in the PDT process along with pulsed NIR light may allow the treatment of 6-7 times bigger tumours than conventional PDT using blue light.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 808 nm, 405 nm
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Near-infrared, Photodynamic therapy, Penetration depth, Wavelength, Optical window. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.