AI-generated summary
The authors compared canine distalization on laser-treated and untreated sides of the same mouth in 40 orthodontic patients, along with gingival crevicular fluid cytokine levels and pain scores. They report that the laser side showed a statistically significant difference in tooth movement and lower pain scores than the control side. The abstract describes the findings as implying faster tooth movement with less pain, but it is a single split-mouth study with unclear generalizability.
- Participants
- 40
- Who or what was studied
- 40 orthodontic patients aged about 19.7 years with Angle Class I malocclusion and bimaxillary protrusion undergoing maxillary first premolar extraction and bilateral canine distalization
- Wavelengths
- 980 nm
- Limits stated in the abstract
- The abstract reports only a single split-mouth study in one patient group, and the authors' interpretation of expedited movement is not clearly supported by the measured values and results are described with varying prior evidence.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background And Objectives
A few investigations have detailed the influence of low-level laser therapy (LLLT) on orthodontic tooth movement (OTM), with varying results. The
Objectives Of This Study Were Twofold
to assess the impact of LLLT on OTM and various cytokine levels in gingival crevicular fluid and to contrast the pain levels experienced by patients receiving orthodontic treatment with and without LLLT.
Materials And Methods
This split-mouth randomized controlled prospective study comprised 40 patients with an average age of 19.7±2.4 years with Angle Class I malocclusion combined with bimaxillary protrusion who were advised for extraction of the maxillary first premolar and bilateral canine distalization. The control-side canine was distalized solely by the coil spring. On the test arm, a low-level gallium-aluminum-arsenide semiconductor diode laser operating at 980 nm and 100 mW with a continuous-wave energy of 8 J/cm2 was used. The canine distalization on either side was measured with a digital caliper following the first premolar extraction (TO), one month after treatment (TOTM1), two months later (TOTM2), and three months later (TOTM3). The gingival index and the level of various cytokines were determined by an enzyme-linked immunosorbent assay at the beginning of the study, on the third and seventh days, and at four, eight, and 12 weeks following the canine distalization. The intra-group and inter-group comparisons were carried out using one-way analysis of variance (ANOVA) and t-tests, respectively, at a 5% significance level.
Results
The results show a highly statistically significant difference in the extent of canine distalization in the test group (TOTM1=2.92±0.44; TOTM2=1.04±0.1; TOTM3=0.62±0.21 mm) in contrast to the control group (TOTM1=3.23±0.8; TOTM2=2.65±0.2; TOTM3=2.11±0.24 mm) (p<0.01). After three months of canine distalization, the laser and control group had 34 and 27 patients with mild gingivitis, respectively. Interleukin-1β and interleukin-6 concentrations surged with values of 0.74±0.13 and 0.049±0.001 pg/g at seven days following treatment in the laser group, respectively. The difference in tumor necrosis factor concentration between the groups was shown to be highly statistically significant in all treatment phases (p<0.001). The differences in the epidermal growth factor and microglobulin levels were found to be statistically significant within both groups from T0 to T5. The average visual analog scale (VAS) scores at several subsequent evaluations of the laser and control groups were found to be highly statistically significant.
Conclusion
The findings imply that when the periodontal microenvironment is stimulated by orthodontic force, several paramount cytokines are released, triggering an ordered sequence of biological processes that appear to expedite OTM with reduced associated pain.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 980 nm
- Energy density (fluence)
- 8 J/cm2
- Power
- 100 mW
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Low-level laser therapy, Control group, Visual analogue scale. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.