AI-generated summary
The authors used an Er,Cr:YSGG laser on extracted bovine teeth to measure how much intra-canal dentine was removed at different tip types and power settings. They report that tip type had a statistically significant effect on ablation rate and efficiency, and that ablation improved with higher power and/or larger tip diameter, with tip diameter having the stronger influence. The study was conducted in vitro on bovine teeth, so results may not transfer directly to clinical use.
- Who or what was studied
- Ninety intact extracted bovine teeth, sectioned into testing cylinders and divided into three groups
- Limits stated in the abstract
- The study was in vitro using extracted bovine teeth, and the authors state that further investigations and system improvements are required.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
The full abstract is not shown here because it is protected by the publisher’s copyright. Read it on link.springer.com.
Record from PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Power
- 1500 mW, 1750 mW, 2000 mW