Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Devices & Dosimetry

In Vitro Mean Red Blood Cell Volume Change Induced by Diode Pump Solid State Low-Level Laser of 405 nm

It was suggested that LLL can reduce RBC volume possibly because of the increased free intracellular Ca(+2) concentrations, which activate Ca(+2)-dependent K(+) channels with consequent K(+) ion efflux and cell shrinkage.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors studied the effect of a 405 nm diode pump solid state low-level laser on human red blood cells in blood samples kept in vitro, with exposure times of 20 to 50 minutes. They report that mean red blood cell volume decreased significantly, with the largest effect at 40 minutes. The authors suggest a possible mechanism involving increased intracellular calcium and potassium efflux, but this was an in vitro study.

Who or what was studied
Human red blood cells from blood samples collected into EDTA-containing tubes (in vitro)
Wavelengths
405 nm
Limits stated in the abstract
The study was conducted in vitro on isolated blood samples, so results may not reflect effects in living people.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Objective

This study was conducted to investigate the effects of low-level laser (LLL) doses on human red blood cell volume. The effects of exposure to a diode pump solid state (DPSS) (λ = 405 nm) laser were observed.

Background Data

The response of human blood to LLL irradiation gives important information about the mechanism of interaction of laser light with living organisms. Materials and methods Blood samples were collected into ethylenediaminetetraacetic acid (EDTA)-containing tubes, and each sample was divided into two equal aliquots, one to serve as control and the other for irradiation. The aliquot was subjected to laser irradiation for 20, 30, 40, or 50 min at a fixed power density of 0.03 W/cm(2). Mean cell volume (MCV) and red blood cell (RBC) counts were measured immediately after irradiation using a computerized hemtoanalyzer.

Results

Significant decrease in RBC volume (p < 0.05, p < 0.0001, p < 0.0001, and p < 0.05, respectively) was induced with variation in laser doses. The highest response was observed with an exposure time of 40 min. This result was reproduced in RBCs suspended in a buffered NaCl solution. In contrast to this finding, laser-induced RBC volume change was completely abolished by suspending RBCs in a solution containing a higher concentration of EDTA.

Conclusions

It was suggested that LLL can reduce RBC volume possibly because of the increased free intracellular Ca(+2) concentrations, which activate Ca(+2)-dependent K(+) channels with consequent K(+) ion efflux and cell shrinkage.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
405 nm

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Laser. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies