AI-generated summary
The authors report a randomized controlled trial of 33 patients receiving 64 dental implants, comparing 808-nm laser therapy with a control group. They found no difference between groups in implant stability quotient change or in peri-implant bone radiographic changes over 4 to 6 months. The authors conclude that the laser did not influence implant stability in healed sites.
- Participants
- 33
- Who or what was studied
- Patients receiving dental implants in healed sites, randomly allocated to low-level laser therapy or control groups; 64 implants placed in 33 patients.
- Wavelengths
- 808 nm
- Limits stated in the abstract
- The abstract does not describe the sample size calculation or the number of patients per group, and it reports only a single outcome time point, 4 to 6 months after placement.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
The present study aims to assess the influence of low-level laser therapy (LLLT) on stability in implants placed in healed sites.
Material And Methods
The present study followed the SPIRIT statement and is reported according to CONSORT. Patients were randomly allocated to LLLT or control groups. LLLT consisted in the application of 808-nm GaAlA laser applied before the preparation of the implant bed and after suturing (80 seconds; 11J/cm2). Implant stability quotient (ISQ) and the distance between the implant platform to the alveolar bone crest (millimeters) were assessed at implant placement (T0) and the abutment selection phase (4-6 months, Ta).
Results
A total of 64 implants were placed in 33 patients. The insertion torque ranged from 10 to 70 N.cm (mean 43.23; SD ±16.82). The T0 ISQ ranged from 18 to 95.5 (mean 61.7; SD ±18.23) and the crestal bone radiographic distance was 2.03 mm (SD±1.27). At Ta, the ISQ ranged from 39 to 90 (mean 64.2; SD±9.84), and the mean crestal bone radiographic loss was 1.70mm (SD±1.65). However, no differences were observed when LLLT and control groups were compared with ISQ difference (Ta-T0; p=0.598) or radiographical peri-implant alterations (p=0.531).
Conclusion
LLLT did not influence the implant stability in implants placed in healed sites compared to a control group.
Trial Registration
ReBEC, RBR-35TNJ7 . Registered May 23, 2018.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Energy density (fluence)
- 11J/cm2
How to read a trial: what to check before relying on this kind of research.
Terms in this paper: Low-level laser therapy, Laser, Randomized controlled trial, Trial registration, Control group. Each links to its definition in the glossary.