AI-generated summary
The authors used an infrared camera to map the backside temperature of a thin black aluminum sheet during a cryogen spurt, since direct surface measurement is hindered by liquid cryogen. The measured temperature distribution was approximately gaussian, and calculations for skin showed large temperature discrepancies between uniform and nonuniform cooling models at radii greater than 2.5 mm. The authors conclude that radial temperature gradients should be considered during cryogen spray cooling.
- Limits stated in the abstract
- The temperature distribution was estimated from a backside measurement on an aluminum sheet and modeled calculations rather than measured directly in tissue.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.