Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Oral & Dental

Injectable platelet rich fibrin versus low-level laser therapy for orthodontic tooth movement: A clinical split-mouth study

Thus, i-PRF is more effective than LLLT in accelerating orthodontic tooth movement. Further multicentre trials are recommended.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors compared injectable platelet rich fibrin (i-PRF) with low-level laser therapy (LLLT) for speeding orthodontic tooth movement in a split-mouth study of 20 patients aged 18 to 25. They report that space closure was faster on the i-PRF side than on the LLLT side over four months. The abstract notes that multicentre trials are recommended.

Participants
20
Who or what was studied
20 patients aged 18 to 25 years undergoing orthodontic treatment
Wavelengths
980 nm
Limits stated in the abstract
The abstract describes a small single split-mouth clinical study and recommends further multicentre trials.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Accelerating tooth movement during orthodontic treatment is a growing focus in clinical orthodontics. Techniques like injectable platelet rich fibrin (i-PRF) and Low-Level Laser Therapy (LLLT) have demonstrated encouraging results. Hence, 20 patients aged 18-25 years were enrolled and one side of their maxillary arch was injected with intraligamental and submucosal i-PRF and the opposite side with LLLT (980nm, 100mW). Measurements were taken using digital vernier calliper on distal surface of canine to mesial surface of second premolar monthly for four months. The mean rate of space closure on i-PRF side (right) was significantly higher (2.85 ± 0.47 mm) than LLLT side (2.05 ± 0.28 mm; p<0.001). The left side (control group) showed no significant difference (p=0.833). Thus, i-PRF is more effective than LLLT in accelerating orthodontic tooth movement. Further multicentre trials are recommended.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
980nm
Power
100mW

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Low-level laser therapy, Laser, Control group. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies

Oral & Dental

Evaluation of the effectiveness of repeated piezocision versus repeated low-level laser therapy in the acceleration of upper canine retraction in terms of dentoalveolar and periodontal changes: A three-arm randomized controlled clinical trial

While both repeated piezocision and LLLT accelerate upper canine retraction during the initial three months without harming periodontal health, piezocision seems to be more effective than LLLT in speed and time reduction.

Study · November 18, 2026 · Alfailany DT et al.