The authors conducted a prospective observational study of 60 patients aged 50 and older receiving routine dental treatment, using diode lasers for hemostasis. They report that laser-mediated hemostasis was associated with shorter bleeding control times, and that full extraction socket recovery was observed at 2 to 4 weeks with no reported complications. The study's observational design, without a control group, limits how strongly these findings can be interpreted.
- Participants
- 60
- Who or what was studied
- Patients aged 50 years and older (average 63.35 years) at risk of postoperative bleeding after routine dental treatment
- Wavelengths
- 810, 635, 980 nm
- Limits stated in the abstract
- The study is a prospective observational design without a control group, so the reported associations cannot establish that laser therapy caused the observed outcomes.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background/Objective
Laser therapy has gained attention in dental practice to minimize bleeding and enhance blood clot formation. This study aimed to explore the utilization and to compare the clinical efficacy of laser-mediated hemostasis for older patients receiving routine dental treatment.
Methods
A prospective observational study was conducted across research networks between October 2023 and August 2024, involving 60 patients aged 50 years and older (average = 63.35 years) at risk of postoperative bleeding following dental treatments. Additionally, laser therapy for hemostasis was selected and provided among calibrated operators. A single researcher performed data collection. Before statistical analysis, data verification and clinical assessment were conducted by the operators and researcher. A clinical cut-off for hemostasis was set at 5 min. Two diode laser machines were used namely, an 810 nm and dual wavelengths of 635 nm and 980 nm.
Results
There were 94 extraction sockets, 28 procedures of scaling and root planing and 18 procedures of minor oral surgery. Combining laser ablating sulcular fiber and photobiomodulation initiating blood clot formation was a preferable hemostatic technique for extraction socket, while photobiomodulation alone was a preferred technique for soft tissue hemostasis (p < 0.001). All operators confirmed that 97.86 percent of bleeding events achieved more rapid hemostasis. 61.43 percent of bleeding events clinically achieved hemostasis within 5 min by using laser-mediated hemostasis alone (p = 0.092). Full recovery of the extraction socket was significantly observed during the 2- to 4-week follow-up period (p = 0.005). No clinical complications were reported.
Conclusions
Laser-mediated hemostasis effectively reduced hemostatic duration, prevented postoperative bleeding and promoted wound healing in older patients undergoing routine dental treatment.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 810 nm, 635 nm, 980 nm
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Photobiomodulation, Observational study, Wound healing. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.