AI-generated summary
The authors describe a case report of one 60-year-old patient receiving two metal-ceramic crowns, in which three laser wavelengths were used as adjuncts. They report that the lasers were successfully applied in this case, but the abstract describes a single patient and offers no comparison group.
- Participants
- 1
- Who or what was studied
- One 60-year-old patient receiving two metal-ceramic crowns
- Wavelengths
- 660 nm
- Limits stated in the abstract
- The study is a single case report, so no generalizable conclusions can be drawn from the abstract.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
The increasing concern and the search for conservative dental treatments have resulted in the development of several new technologies. Low and high power lasers can be cited as one of these new technologies. Low power lasers act at cellular level leading to pain reduction, modulation of inflammation, and improvement of tissue healing. High power lasers act by increasing temperature and have the potential to promote microbial reduction and ablation of hard and soft tissues. The clinical application of both low and high power lasers requires specific knowledge concerning laser interaction with biological tissues, so that the correct irradiation protocol can be established. The present case report describes the clinical steps of two metal-ceramic crowns development in a 60-year-old patient. Three different laser wavelengths were applied throughout the treatment with different purposes: Nd:YAG laser (1,064 nm) for dentin decontamination, diode (660 nm) for soft tissue biomodulation, and Er:YAG laser (2,940 nm) for inner ceramic surface conditioning. Lasers were successfully applied in the present case report as coadjutant in the treatment. This coadjutant technology can be a potential tool to assist treatment to reach the final success.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 064 nm, 660 nm, 940 nm
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Photobiomodulation, Laser, Case report, Inflammation. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.