AI-generated summary
The authors systematically reviewed six in vitro studies that applied light sources to tenocyte cultures, a cell type from tendons. They report that all included studies showed positive effects, such as increased cell proliferation and migration and higher tendon biomarker expression. The authors note that poor standardization of light parameters and a high risk of bias limited firm conclusions.
- Studies included
- 6
- Who or what was studied
- Tenocyte cell cultures (mainly from Achilles tendon) in in vitro studies
- Wavelengths
- 530, 1100 nm
- Limits stated in the abstract
- Only six studies were included, methodological quality was low, reporting of light parameters was non-standardized, and risk of bias was high.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Methods
The PubMed, Scopus, and Web of Science databases were searched up to December 9, 2019 for in vitro studies that used light sources on tenocyte cultures. A 13-item checklist was used to assess methodological quality of the studies and the risk of bias was assessed using the Risk of Bias Assessment tool for Non-randomized Studies tool.
Results
Six studies were included. Tenocytes from the Achilles tendon were used by 83.3% of the studies, with 16.7% utilizing the deep digital flexor tendon, with cells in passage 2 to 5. Four studies used lasers and the other 2 used light-emitting diode or intense pulsed light, in wavelengths ranges from 530 to 1100 nm. The application of light to tenocytes resulted in positive effects reported by all studies, including an increase in cell proliferation and migration, and higher protein and gene expression of tendon biomarkers. Studies presented a lack of standardization on reporting light stimulation parameters and experimental methodologies, leading to low methodological quality. There was a high risk of selection, performance, detection, and reporting bias.
Conclusions
All studies showed positive effects after light stimulation on tenocytes, regardless of the light source used. However, the lack of standardized data on light stimulation parameters, experimental setup, and the studies' main limitations hindered representative conclusions and comparisons amongst studies' main outcomes.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 530 to 1100 nm
How to read a review: what to check before relying on this kind of research.
Terms in this paper: Systematic review, Risk of bias, Light-emitting diode. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.