Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Skin & Wound Healing

Low-fluence vs. standard fluence hair removal: a contralateral control non-inferiority study

Lower fluence diode laser, delivered under conditions of vacuum and using larger spot sizes, can provide significant hair reduction.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors compared laser hair removal using standard settings with a lower-fluence 800 nm diode laser delivered by a larger vacuum-assisted handpiece, treating one axilla of each of 14 participants. In 11 who completed the study, both sides showed significant hair reduction, and the authors report comparable reduction at 3 months and better tolerability for the lower-fluence side. The sample is small and this is a pilot study.

Participants
14
Who or what was studied
Healthy adults undergoing axillary hair removal; 14 enrolled, 11 completed the study and follow-up
Wavelengths
800 nm
Limits stated in the abstract
Pilot study with a small sample (11 completers) and no statement of formal statistical power in the abstract.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Introduction

Laser hair removal at lower fluences, delivered under certain conditions, may retain the efficacy of high-fluence lasers while improving tolerability. We performed a pilot study comparing the efficacy, safety and tolerability of laser hair removal using traditional settings compared to lower fluences, delivered from a larger handpiece and under vacuum.

Material And Methods

Fourteen healthy participants underwent 5 axillary hair removal treatments with an 800 nm diode laser at 1-month intervals, with follow-up 1 and 3 months after the 5th treatment. In all patients, one side was treated with standard parameters using a 9×9 mm chilled tip and gel, while the contralateral side was treated using a 22×35 mm vacuum-assisted handpiece at fluences up to 12 J/cm(2). Follow-up assessments were performed after each treatment and at each follow-up visit, and included photography and questionnaires.

Results

Eleven participants completed the study and follow-up. All experienced significant hair removal in all treated areas. At the 3-month follow-up visit, the high-fluence and low-fluence treated axillae demonstrated comparable hair reduction. Participants found the lower fluence treatments to be more tolerable. No adverse events were reported.

Conclusion

Lower fluence diode laser, delivered under conditions of vacuum and using larger spot sizes, can provide significant hair reduction.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
800 nm

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Fluence, Laser, Pilot study. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies