AI-generated summary
The authors randomized 80 healthy young adults to low intensity laser, 20% benzocaine, pressure, or light touch before palatal anesthetic injection and rated pain on a visual analog scale. Median pain scores were lowest in the laser group, but the authors report no statistically significant difference among the four techniques.
- Participants
- 80
- Who or what was studied
- Healthy volunteers aged 18 to 25 years, 40 females and 40 males, randomized into four groups of 20.
- Wavelengths
- 790 nm
- Limits stated in the abstract
- The abstract reports no statistically significant difference among groups, and the sample is limited to healthy young adults undergoing a single palatal injection.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
The full abstract is not shown here because it is protected by the publisher’s copyright. Read it on journals.sagepub.com.
Record from PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 790 nm
- Energy density (fluence)
- 27.69 J/cm2
- Power
- 30 mW
- Total energy
- 3.6 J
How to read a trial: what to check before relying on this kind of research.
Terms in this paper: Laser, Visual analogue scale, Fluence. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.