AI-generated summary
The authors exposed wild-type and DNA-repair-deficient Escherichia coli cultures to red and infrared low-intensity lasers at very high fluences of 250 to 1000 J/cm2. They report that these high fluences were lethal, induced filamentation, and altered cell morphology. The authors note that the findings concern unusually high fluences and point to the need for accurate dosimetry in therapeutic protocols.
- Who or what was studied
- Cultures of wild-type (AB1157), endonuclease III-deficient (JW1625-1), and endonuclease IV-deficient (JW2146-1) Escherichia coli bacteria in exponential and stationary growth phases
- Limits stated in the abstract
- The study uses bacterial cultures rather than human or animal subjects, and the abstract does not state the wavelengths used.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Semiconductor laser devices are readily available and practical radiation sources providing wavelength tenability and high monochromaticity. Low-intensity red and near-infrared lasers are considered safe for use in clinical applications. However, adverse effects can occur via free radical generation, and the biological effects of these lasers from unusually high fluences or high doses have not yet been evaluated. Here, we evaluated the survival, filamentation induction and morphology of Escherichia coli cells deficient in repair of oxidative DNA lesions when exposed to low-intensity red and infrared lasers at unusually high fluences. Cultures of wild-type (AB1157), endonuclease III-deficient (JW1625-1), and endonuclease IV-deficient (JW2146-1) E. coli, in exponential and stationary growth phases, were exposed to red and infrared lasers (0, 250, 500, and 1000 J/cm2) to evaluate their survival rates, filamentation phenotype induction and cell morphologies. The results showed that low-intensity red and infrared lasers at high fluences are lethal, induce a filamentation phenotype, and alter the morphology of the E. coli cells. Low-intensity red and infrared lasers have potential to induce adverse effects on cells, whether used at unusually high fluences, or at high doses. Hence, there is a need to reinforce the importance of accurate dosimetry in therapeutic protocols.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Energy density (fluence)
- 1000 J/cm2
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Near-infrared, Wavelength, Dosimetry. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.