AI-generated summary
The authors report a randomized split-mouth trial in 20 subjects with 40 orthodontic mini-implants, comparing sites given 635 nm diode laser irradiation with untreated control sites on the opposite side. Stability measured by Periotest was higher in the laser-treated group at 30 and 60 days, and all mini-implants survived. The authors conclude that 635 nm laser irradiation was associated with increased secondary stability of orthodontic mini-implants, and pain levels did not differ between sides.
- Participants
- 20
- Who or what was studied
- 20 adult subjects (13 women, 7 men; mean age 32.5 years) receiving orthodontic mini-implants in the maxilla
- Wavelengths
- 635 nm
- Limits stated in the abstract
- The abstract does not describe a sham control or blinding, and the sample is small.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
The study aimed to clinically estimate an influence of a 635 nm diode laser on the stability of orthodontic mini-implants, to assess mini-implants loss, and to evaluate a pain level after the treatment.
Materials And Methods
The randomized clinical split-mouth trial included 20 subjects (13 women and 7 men; age: 32.5 ± 6.1 years), 40 implants (RMO, West Colfax Ave., Denver, CO, USA) with a diameter 1.4 mm and length of 10 mm. Mini-implants were placed in the area of the attached gingiva between the second premolar and first molar teeth, 2 mm below the mucogingival junction of both sides of the maxilla. Each implant on the right side (G1, n = 20) of the maxilla was irradiated with a diode laser, and the implants on the opposite side (left, G2, n = 20) were a control group (without laser irradiation). The 635-nm laser parameters; dose: 10 J per point (20 J/cm2), time: 100 s per point, two points (irradiation on a buccal, and a palatal side of the alveolus/implant), the total energy per session 20 J. Laser application protocol: immediately and 3, 6, 9, 12, 15, and 30 days after surgery. The total energy after all therapeutic sessions was 140 J. The implants' stability was measured employing a Periotest device (Periotest Test Value-PTV) immediately and 3, 6, 9, 12, 15, 30, and 60 days after the insertion of the mini-implants.
Results
We found significantly higher secondary stability, lower mean PTV (6.18 ± 5.30) and (1.51 ± 2.25), for self-drilling mini-implants (G1, test group) in contrast to the control, G2 group (9.17 ± 8.25) and (5.00 ± 3.24), after 30 (p = 0.0003) and 60 days (p = 0.0000). Moreover, the analysis of the mini-implants stability after 635-nm diode laser application revealed significant higher stability in comparison with none irradiated implants (G2 group) after 3 days. (p = 0.0000) There was no significant difference in pain level measured on the NRS-11 scale on both sides of the maxilla. (p = 0.3665) An important finding was that all inserted mini-implants survived during a two-month observation period.
Conclusions
635-nm diode laser at laser irradiation increases the secondary stability of orthodontic mini-implants.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 635 nm
- Energy density (fluence)
- 20 J/cm2
- Total energy
- 10 J, 20 J, 140 J
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Laser, Low-level laser therapy, Control group, Dose. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.