AI-generated summary
The authors used computer simulations of light and heat transport to design an optode for delivering light to deep, large cortical volumes in non-human primate brain without inserting fibers into the cortex. They report that larger fiber diameter and numerical aperture reduce surface thermal increases, and that a four-fiber configuration with 4 mm spacing could cover 200 to 500 mm3 of tissue. The study is simulation-based and includes no animal or human experiments.
- Who or what was studied
- Non-human primate cortex, modeled by simulation
- Limits stated in the abstract
- The findings come from Monte Carlo simulations only, with no experimental validation in animals or tissue.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Objective
We propose the design of an optode for safe and efficient optical stimulation of a large volume of NHP cortex, down to 3-5 mm depths without inserting fibers into the cortex. APPROACH: Monte Carlo simulations of optical and thermal transport have been carried out using the Geant4 application for tomographic emission (GATE) platform. Parameters such as the fiber diameter, numerical aperture, number of fibers and their geometrical arrangement have been studied. Optimal hardware parameters are proposed to obtain homogeneous fluence above the fluence threshold for opsin activation without detrimental thermal effects. MAIN
Results
The simulations show that a large fiber diameter and a large numerical aperture are preferable since they allow limiting power concentration and hence the resulting thermal increases at the brain surface. To obtain a volume of 200-500 mm3 of brain tissues receiving a fluence above the opsin activation threshold for optogenetics or below a phototocixity threshold for photobiomodulation, a 4 fibers configuration is proposed. The optimal distance between the fibers was found to be 4 mm. A practical implementation of the optode has been performed and the corresponding fluence and thermal maps have been simulated.
Significance
The present study defines a method to optimize the design of optode and the choice of stimulation parameters for optogenetics and more generally light delivery to deep and large volumes of tissues in NHP brain with a controlled irradiance dosimetry. The general guidelines are the use of silica fibers with a large numerical aperture and a large diameter. The combination of several fibers is required if large volumes need to be stimulated while avoiding thermal effects.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Fluence, Photobiomodulation, Irradiance, Dosimetry. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.