AI-generated summary
The authors irradiated isolated bovine liver mitochondria with 980 nm laser light at powers from 0.1 to 1.4 W and measured enzyme activity, ATP production, oxygen consumption and reactive oxygen species. They report that lower powers inhibited ATP production and raised oxidative stress, intermediate powers had no effect, and higher powers increased ATP synthesis, with effects centered on Complexes III and IV. Because this was an in vitro study of isolated mitochondria rather than living tissue, the findings cannot be directly applied to people.
- Who or what was studied
- Isolated bovine liver mitochondria (in vitro)
- Wavelengths
- 980, 808, 1064, 633 nm
- Limits stated in the abstract
- The study used isolated bovine liver mitochondria in vitro, so the results do not establish effects in living organisms or humans.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Photobiomodulation with 808 nm laser light electively stimulates Complexes III and IV of the mitochondrial respiratory chain, while Complexes I and II are not affected. At the wavelength of 1064 nm, Complexes I, III, and IV are excited, while Complex II and some mitochondrial matrix enzymes seem to be not receptive to photons at that wavelength. Complex IV was also activated by 633 nm. The mechanism of action of wavelengths in the range 900-1000 nm on mitochondria is less understood or not described. Oxidative stress from reactive oxygen species (ROS) generated by mitochondrial activity is an inescapable consequence of aerobic metabolism. The antioxidant enzyme system for ROS scavenging can keep them under control. However, alterations in mitochondrial activity can cause an increment of ROS production. ROS and ATP can play a role in cell death, cell proliferation, and cell cycle arrest. In our work, bovine liver isolated mitochondria were irradiated for 60 sec, in continuous wave mode with 980 nm and powers from 0.1 to 1.4 W (0.1 W increment at every step) to generate energies from 6 to 84 J, fluences from 7.7 to 107.7 J/cm2, power densities from 0.13 to 1.79 W/cm2, and spot size 0.78 cm2. The control was equal to 0 W. The activity of the mitochondria's complexes, Krebs cycle enzymes, ATP production, oxygen consumption, generation of ROS, and oxidative stress were detected. Lower powers (0.1-0.2 W) showed an inhibitory effect; those that were intermediate (0.3-0.7 W) did not display an effect, and the higher powers (0.8-1.1 W) induced an increment of ATP synthesis. Increasing the power (1.2-1.4 W) recovered the ATP production to the control level. The interaction occurred on Complexes III and IV, as well as ATP production and oxygen consumption. Results showed that 0.1 W uncoupled the respiratory chain and induced higher oxidative stress and drastic inhibition of ATP production. Conversely, 0.8 W kept mitochondria coupled and induced an increase of ATP production by increments of Complex III and IV activities. An augmentation of oxidative stress was also observed, probably as a consequence of the increased oxygen consumption and mitochondrial isolation experimental conditions. No effect was observed using 0.5 W, and no effect was observed on the enzymes of the Krebs cycle.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 980 nm, 808 nm, 1064 nm, 633 nm, 900-1000 nm
- Energy density (fluence)
- 107.7 J/cm2
- Power
- 1.4 W, 0.1 W, 0 W, 0.2 W, 0.7 W, 1.1 W
- Total energy
- 84 J
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Reactive oxygen species, Oxidative stress, Adenosine triphosphate, Photobiomodulation, Laser, Mitochondria, Wavelength. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.