AI-generated summary
The authors measured forearm changes in oxygenated hemoglobin and oxidized cytochrome c oxidase using near-infrared spectroscopy during and after photobiomodulation with lasers at three wavelengths and an LED at 810 nm. They report that all lasers increased both measures significantly, with the 1064 nm laser sustaining the increase longer, and that the 810 nm LED also produced significant rises compared with sham stimulation.
- Who or what was studied
- Two groups of 10 healthy participants
- Wavelengths
- 800, 850, 1064, 810 nm
- Limits stated in the abstract
- The abstract describes a small sample of healthy volunteers measured on the forearm only, so the findings may not generalize to other tissues or clinical populations.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Our group previously examined 8 min photobiomodulation (PBM) by 1064 nm laser on the human forearm in vivo to determine its significant effects on vascular hemodynamics and cytochrome c oxidase redox activity. Since PBM uses a wide array of wavelengths, in this paper, we investigated (i) whether different wavelengths of lasers induced different PBM effects, and (ii) if a light-emitting diode (LED) at a similar wavelength to a laser could induce similar PBM effects. A broadband near-infrared spectroscopy (bbNIRS) system was utilized to assess concentration changes in oxygenated hemoglobin (Δ[HbO]) and oxidized cytochrome c oxidase (Δ[oxCCO]) during and after PBM with lasers at 800 nm, 850 nm, and 1064 nm, as well as a LED at 810 nm. Two groups of 10 healthy participants were measured before, during, and after active and sham PBM on their forearms. All results were tested for significance using repeated measures ANOVA. Our results showed that (i) lasers at all three wavelengths enabled significant increases in Δ[HbO] and Δ[oxCCO] of the human forearm while the 1064 nm laser sustained the increases longer, and that (ii) the 810-nm LED with a moderate irradiance (≈135 mW/cm2) induced measurable and significant rises in Δ[HbO] and Δ[oxCCO] with respect to the sham stimulation on the human forearm.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 1064 nm, 800 nm, 850 nm, 810 nm
- Power density (irradiance)
- 135 mW/cm2
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Photobiomodulation, Light-emitting diode, Laser, Cytochrome c oxidase, Sham, Near-infrared, Irradiance, Wavelength. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.