AI-generated summary
This randomized controlled trial of 44 patients who had 101 third molar extractions reports that a GaAlAs laser (808 nm) applied after extraction was associated with lower postoperative pain scores on a visual analogue scale at 6, 24, and 48 hours than a control group. The authors describe the findings as statistically significant but do not extend them beyond this single trial setting.
- Participants
- 44
- Who or what was studied
- Patients undergoing third molar extractions, mean age 28 years (SD 11.54)
- Wavelengths
- 808 nm
- Limits stated in the abstract
- The abstract does not describe blinding, sample size calculation, or long-term follow-up beyond 48 hours.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
To assess the efficacy of PBMT on reducing postoperative pain scores in patients submitted to third molar extractions.
Material And Methods
A randomized controlled trial (ReBEC:RBR-94BCKZ) was designed according to the SPIRIT and followed the CONSORT. Patients were randomly allocated according to control or PBMT groups. PBMT consisted of the application of GaAlAs laser (808nm;50mW) applied in six points (1.23 min;11 J/cm2) after extraction. Pain scores were assessed using the Visual Analogue Scale (VAS) in millimeters evaluated after 6 (T6), 24 (T24), and 48 (T48) hours. The Wilcoxon Mann-Whitney test was used to check for possible associations between VAS scores and treatment groups.
Results
A total of 101 third molar extractions were performed in 44 patients. The mean age was 28 years old(SD±11.54). Comparing control and intervention, PBMT group showed a significant effect on the reduction of postoperative pain at T6(mean VAS=0.9; C.I:0.63-1.16) compared to control (mean VAS=2.5;C.I:2.1-2.88)(p<0.001). The same statistically significant effect on the reduction of postoperative pain was observed at T24 (PBMT mean VAS=0.72;C.I:0.51-0.93; control mean VAS=2.86;C.I:2.40-3.31;p<0.001) and T48 (PBMT mean VAS=0.64;C.I:0.36-0.92; control mean VAS=2.86;C.I:2.37-3.34;p<0.001).
Conclusions
PBMT significantly reduce the postoperative pain scores when assessed 6, 24, and 48 hours after third molar extractions.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 808nm
- Energy density (fluence)
- 11 J/cm2
- Power
- 50mW
How to read a trial: what to check before relying on this kind of research.