Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Devices & Dosimetry

Smartphone-Driven Low-Power Light-Emitting Device

PWM value is linearly calibrated to obtain accurate intensity. The device can control the intensity of illumination, and so, it can find application in varied scenarios.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors describe a smartphone-driven low-power light-emitting device intended for colour therapy, with a control unit and colour probe powered and controlled through a smartphone app over USB On-The-Go. Light intensity is set by pulse width modulation without feedback and was linearly calibrated by measuring output at 10 percent steps. The abstract reports that the device can control illumination intensity but does not report any clinical testing of therapeutic outcomes.

Limits stated in the abstract
The abstract reports no clinical or human testing and no therapeutic outcome data, and intensity control relies on calibration because the device has no feedback.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Low-level light (laser) therapy (LLLT) has been widely researched in the recent past. Existing LLLT studies were performed based on laser. Recently, studies using LED have increased. This study presents a smartphone-driven low-power light-emitting device for use in colour therapy as an alternative medicine. The device consists of a control unit and a colour probe. The device is powered by and communicates with a smartphone using USB On-The-Go (OTG) technology. The control unit controls emitting time and intensity of illumination with the configuration value of a smartphone application. Intensity is controlled by pulse width modulation (PWM) without feedback. A calibration is performed to resolve a drawback of no feedback. To calibrate, intensity is measured in every 10 percent PWM output. PWM value is linearly calibrated to obtain accurate intensity. The device can control the intensity of illumination, and so, it can find application in varied scenarios.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Low-level laser therapy, Laser, Light-emitting diode. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies