In this animal study of rats with a crushed sciatic nerve, the authors compared high-intensity laser therapy (1064 nm) with photobiomodulation (650 nm) and an untreated control group. They report that high-intensity laser therapy was associated with better functional scores, electrophysiological values and myelination ratios than the other groups. Because this was a rat study with a small sample of 33 animals, the findings may not apply directly to humans.
- Participants
- 33
- Who or what was studied
- Rats with sciatic nerve crush injury
- Wavelengths
- 1064, 650 nm
- Limits stated in the abstract
- The study was conducted in 33 rats, so its results may not translate directly to humans.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
The purpose of this research was to evaluate the therapeutics effects of photobiomodulation and high intensity laser therapy after a sciatic nerve crush injury. Following the crush injuries of sciatic nerve, 33 rats were randomly divided into three groups. The injured sciatic nerves of the rats in the control group were left to heal spontaneously, whereas HILT (120 J/session and 1064 nm) and photobiomodulation therapy (PBM) (2.4 J/session and 650 nm) were started immediately after surgery and performed once every 3 days (10 session in total) during the postoperative period. Electrophysiological evaluations were conducted before surgery and at the end of the healing period. The Sciatic Functional Index (SFI) was assessed before surgery and at the end of the healing period. The ratio of the inner axonal diameter to the total outer axonal diameter (g-ratio) and schwann cells per square micrometer were histomorphometrically evaluated. At the end of the 30-day healing period, significantly better SFI scores were noted in the HILT group compared with PBM (p=0.002) and control (p < 0.001) groups. HILT exhibited positive effects on latency and duration values when compared PBM (p=0.002, p=0.014) and control (p=0.003, p < 0.001) groups. The number of nerves with an optimum g-ratio was higher in the HILT group which indicates a better rate of myelination. Functional, histomorphometric, and electrophysiological investigations of the present study revealed that HILT seems to be a superior treatment modality for peripheral nerve regeneration.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 1064 nm, 650 nm
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Photobiomodulation, High-intensity laser therapy, Photobiomodulation therapy, Control group, Laser. Each links to its definition in the glossary.