Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Oral & Dental

The effect of Photobiomodulation therapy on implant stability in patients receiving dental implants- a systematic review and meta-analysis

The PBM therapy on implant stability has yielded mixed results. While some studies have demonstrated a positive effect, others have reported no significant impact.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors report a systematic review and meta-analysis of 15 studies, with 8 included in the quantitative analysis, on photobiomodulation effects on implant stability in patients. Results were mixed: the control group performed better at 2, 4 and 8 weeks, the experimental group at 3 weeks, and no difference was seen at 6 and 12 weeks. The authors conclude that further research is needed.

Studies included
15
Who or what was studied
Patients receiving dental implants
Limits stated in the abstract
The abstract notes that cumulative data are limited and that the findings are mixed, with some studies showing a positive effect and others no significant impact.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Background

The use of photobiomodulation (PBM) therapy in implant dentistry for enhancing the osseointegration is proven in many studies. However, the cumulative data of its effect around dental implants in patients is limited.

Objectives

The purpose of the present study was to evaluate the effect of the PBM therapy on primary and secondary implant stability.

Material And Methods

The studies included in the review and meta-analysis were selected according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and the PICOS criteria. The RoB 2 tool was used for assessing the risk of bias and the RevMan software, v. 5.4, was used for meta-analysis. Quantitative analysis was done using two tools considering the implant stability measurement using Ostellmeter and radiographs as the outcome. The mean and standard deviation (M ± SD) values for implant stability as well as the sample size were extracted from the articles, and the inverse variance method with random effects was used for meta-analysis. The forest plots for all time intervals were inspected to estimate the heterogeneity.

Results

A total of 117 articles were initially retrieved, out of which 62 remained after duplicate removal. 15 articles were included in the review for qualitative analysis and 8 were eligible for quantitative analysis. The meta-analysis showed that at 2 weeks, 4 weeks and 8 weeks, the control group showed better result than experimental group, at 3 weeks the implant stability favoured the experimental group whereas at 6 and 12 weeks there was no difference seen between control and experimental group.

Conclusions

The PBM therapy on implant stability has yielded mixed results. While some studies have demonstrated a positive effect, others have reported no significant impact. Consequently, further research is warranted to fully elucidate the effects of PBM therapy on implant stability.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

How to read a review: what to check before relying on this kind of research.

Terms in this paper: Photobiomodulation, Meta-analysis, Photobiomodulation therapy, Systematic review, Control group, Heterogeneity, Risk of bias, Sample size. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies