AI-generated summary
This randomized controlled trial compared a laser-based protocol after tooth extraction with a standard extraction procedure in about 53 simple extractions. The authors report that bone density increase at 4 months was significantly higher in the laser group, and no post-operative pain, bleeding or swelling was reported in that group. The authors describe the laser protocol as safe and effective for post-extraction bone healing.
- Participants
- 53
- Who or what was studied
- Patients undergoing simple tooth extractions, randomized to laser or control group
- Wavelengths
- 2940, 1064 nm
- Limits stated in the abstract
- The abstract does not describe the sample size per group or a detailed follow-up beyond 4 months, and the study is a single trial.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
Post-extraction bone resorption may affect the outcome of ensuing restorations.
Purpose
This study aimed to evaluate a comprehensive laser post-extraction protocol by comparing resulting alveolar bone regeneration with that obtained after standard extraction procedure.
Materials And Methods
About 53 simple extractions were randomized to either laser or control group. In the laser group, erbium (Er:YAG; 2940 nm) and neodymium (Nd:YAG; 1064 nm) lasers were used for degranulation, disinfection, de-epithelialization of the surrounding gingiva, clot stabilization, and photobiomodulation. The primary outcome measure was change in bone density in the extraction area between day 1 and 4 months after extraction. Patients were monitored for potential side effects.
Results
Increase in bone density at the follow-up CBCT was significantly higher in laser than in control group (p < 0.001). No post-operative pain, bleeding, or swelling was present in the laser group. In the control group, one patient had bleeding 3-5 days after extraction, two patients had swelling and three patients reported post-operative pain rated 3-5 on a 0-10 pain scale up to 3 days after extraction.
Conclusions
The proposed laser post-extraction procedure is a safe and effective method to improve post-extraction bone healing.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 2940 nm, 1064 nm
How to read a trial: what to check before relying on this kind of research.
Terms in this paper: Laser, Randomized controlled trial, Control group, Photobiomodulation, Primary outcome. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.