AI-generated summary
The authors compared low-level laser therapy at 808 nm and 660 nm with a sham control in 47 people with knee osteoarthritis over eight weeks. They report that the 808 nm group showed greater improvement in knee extensor strength than the 660 nm and sham groups, and that the 660 nm group improved on the 30-second sit-to-stand test. The other functional tests improved in all groups without significant differences between them.
- Participants
- 47
- Who or what was studied
- Individuals with knee osteoarthritis
- Wavelengths
- 808, 660 nm
- Limits stated in the abstract
- The abstract does not describe a limitation; the trial assessed outcomes only one week after the interventions ended, and no certainty rating is given.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
The purpose of this study was to compare the therapeutic effects of low-level laser therapy (LLLT) with 808 and 660 nm wavelength on muscle strength and functional outcomes in individuals with knee osteoarthritis (OA). A total of 47 participants were randomly assigned to the 808 nm, 660 nm, and sham control groups. Two LLLT groups received continuous LLLT with a mean power of 300 mW in different wavelengths at the knee joint 15 min a session three days per week for eight weeks, while the control group received the sham LED treatment. The knee strength and functional performance involving 30-s sit-to-stand, 40 m fast-paced walk, stair climbing, and the TUG test were measured at the baseline and one week after the interventions were completed. The results showed that knee extensor strength was more improved in the 808 nm group as compared to the 660 nm group (p < 0.001, d = 0.57) and the sham control (p < 0.001, d = 0.40), while increased flexor strength was demonstrated in the 808 nm (p = 0.009, d = 0.67) and sham control groups (p < 0.001, d = 0.97). The number of 30-s sit-to-stand was increased only in the 660 nm group (p = 0.006, d = 0.49). All three groups exhibited improvements in the other three functional performance-based tests after the interventions with no statistically significant differences among the groups. In conclusion, both intervention groups improved muscle strength and functional performance as compared to the control group. The 808 nm wavelength group showed better results in knee extensor strength. Therefore, laser therapy is suggested to be integrated into rehabilitation programs to improve muscle strength and functional performance in the population with knee OA.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 660 nm, 808 nm
- Power
- 300 mW
How to read a trial: what to check before relying on this kind of research.
Terms in this paper: Low-level laser therapy, Laser, Osteoarthritis, Randomized controlled trial, Sham, Control group, Wavelength, Light-emitting diode. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.