Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Oral & Dental

The influence of tooth shade on near-infrared light transmission through human dentine and enamel: an in-vitro study

Within the range from 660 to 1100 nm, the longer wavelengths are transmitted better by both enamel and dentine.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors measured how much near-infrared and red light passed through slices of human teeth, comparing tooth shade groups and light sources in an in-vitro study. They report that dentine transmitted about 40% more light than enamel and dentine combined, that longer wavelengths were transmitted better, and that shade affected only 660 nm red light transmission. The study was conducted on extracted teeth outside the body.

Participants
40
Who or what was studied
40 extracted human teeth, sectioned into 3 mm slices of crown (enamel-dentine) and root (dentine only)
Wavelengths
660, 808, 904 nm
Limits stated in the abstract
This is an in-vitro study on extracted teeth, so the findings may not reflect transmission in living tissue.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

This in-vitro study assessed the influence of the shade of human teeth on the transmission of near-infrared light. A total of 40 teeth were used. After cleaning the root surface and removing cementum, the teeth were sectioned into slices 3 mm thick, with each comprising a portion of the crown (enamel-dentine (ED)) and of the root (dentine only). The shade of the crown and the root was measured using a digital spectrophotometer. All samples were irradiated using 660, 808, or 904 nm diode lasers, and a multi-wavelength LED light source (700-1100 nm, Nuralyte®). Using a laser power meter, the percent transmission was calculated. Differences between Vita shade groups A, B, and C were analysed using ANOVA and post-hoc tests. Overall, dentine samples showed approximately 40% greater transmission than samples of enamel and dentine. There were significant influences for shade group and for sample thickness on the transmission of 660 nm light (P < 0.01), but not for other light sources. There was a statistically significant influence of light source on transmission. Across both crown and root samples, the ranking for light transmission from greatest to least was LED (700-1100 nm) > (904 nm = 808 nm) > 660 nm. Within the range from 660 to 1100 nm, the longer wavelengths are transmitted better by both enamel and dentine. The transmission of visible red light (660 nm) was affected by Vita tooth shade, while the transmission of near infrared light (700-1100 nm) was not affected by Vita shade.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
904 nm, 700-1100 nm, 660 nm, 808 nm, 660 to 1100 nm

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Near-infrared, Light-emitting diode, Wavelength, Laser. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies