AI-generated summary
The authors report a randomized, double-blind trial of 60 patients with myofascial temporomandibular disorder pain, split into three groups: a sham LED device, red LED light, and low-level LASER. Both the red LED and LASER groups showed significant pain improvement at later visits compared with the sham group, with no significant difference between the two active treatments. The authors note that the LED device is safer and cheaper, but the abstract does not state the certainty of these findings.
- Participants
- 60
- Who or what was studied
- Patients with myofascial pain related to temporomandibular disorders
- Limits stated in the abstract
- The abstract does not report the wavelengths used and gives no detail on the certainty of the findings or the size of the effects.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Background
Temporomandibular Disorders (TMD) refer to a group of symptoms where pain is the most leading cause to demand a treatment by the patient. Light therapies are of great importance at current times due to its biosafety and non-invasive quality when used for the management of TMD symptoms. This study aimed to evaluate the efficacy of red LED light with low-level LASER in treating TMD patients.
Materials And Methods
A double-blind randomized clinical study was conducted and included 60 patients along 3 groups (20 for each group) presented with myofascial pain related to TMD. Patients were randomly divided into 3 groups. Group A were managed by applying the LED light device into the trigger points without switching the device on. A red LED light was given to group B for 5 min at the tender muscles. Group C were treated by using low-level LASER therapy for 30 s. Patients were evaluated for any improvements regarding the pain score, presence of trigger points, and trismus along 4 visits (1 week interval between each visit). Any side effects related to the 2 devices were also assessed.
Results
Both group B and C patients showed a statistically significant improvement in the pain value (P < 0.05) at the 3rd and 4th visits when compared to group A. Regarding tenderness, there was a reduction in the number of trigger points in both study groups; however, the results were insignificant in group B. Statistics showed insignificant differences between group B & C patients regarding pain and number of trigger points at all visits (P > 0.05).
Conclusion
Both LED light and LASER therapies could effectively relieve pain associated with myogenic TMD as there were no important differences between their outcomes. However, the biosafety and lower cost of the LED light device compared to the LASER should also be considered. Trial Registration This clinical trial was prospectively registered (TCTR ID: TCTR20190507002) on 07/05/2019. URL: http://www.thaiclinicaltrials.org/show/TCTR20190507002.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
How to read a trial: what to check before relying on this kind of research.
Terms in this paper: Laser, Light-emitting diode, Randomized controlled trial, Low-level laser therapy, Trial registration. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.