Free · 13,591 studies indexed

lighttherapyresearch.com is a free index of research on photobiomodulation and light therapy, gathered from the world’s journals and trial registries.

Sections
Oral & Dental

The Use of Diode Low-Power Laser Therapy before In-Office Bleaching to Prevent Bleaching-Induced Tooth Sensitivity: A Clinical Double-Blind Randomized Study

The use of preliminary diode LLLT could represent a valid possibility to reduce the occurrence of tooth sensitivity post-whitening and shorten recovery time in cases where tooth sensitivity occurs.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors randomized 30 patients to receive either a single 810 nm diode laser pre-treatment or a placebo before in-office bleaching with 38% hydrogen peroxide, and recorded cold sensitivity by visual analog scale. The authors report that the laser group's sensitivity scores approached baseline sooner at one hour after bleaching, and they conclude that preliminary laser therapy could reduce post-whitening sensitivity. The abstract notes the study was double-blind and randomized but gives no further detail on outcomes beyond the reported values.

Participants
30
Who or what was studied
30 patients undergoing in-office bleaching with 38% hydrogen peroxide, randomly divided into a test group and a placebo group of 15 each
Wavelengths
810 nm
Limits stated in the abstract
The abstract reports a small sample of 30 patients, reports values that are not clearly labeled, and states no statistical testing or follow-up beyond 48 hours.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

Introduction

The present study aimed to investigate the effectiveness of low-level laser therapy (LLLT) use before in-office bleaching to prevent an increase in the risk and intensity of tooth sensitivity.

Methods

Thirty patients were selected. Before bleaching with 38% hydrogen peroxide, the participants were randomly divided into two groups of 15 subjects. Test group: the patients' teeth were subjected to a preliminary LLLT procedure by an 810 nm diode laser with 0.5 W for 30 s for an energy density of 15 J/cm2 and a group placebo. All patients were instructed to report their cold sensitivity experiences immediately, 1 h, 24 h, and 48 h after the end of bleaching via a VAS score.

Results

The results obtained show an increase in VAS values for both groups (290 and 490 vs. 224 and 234 of baseline time of test and placebo group, respectively); afterward, the VAS value seemingly decreases at 1 h after the end of bleaching, approaching the baseline VAS for the test group (274) in comparison to the placebo group.

Conclusions

The use of preliminary diode LLLT could represent a valid possibility to reduce the occurrence of tooth sensitivity post-whitening and shorten recovery time in cases where tooth sensitivity occurs.

Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
810 nm
Energy density (fluence)
15 J/cm2
Power
0.5 W

How to read a single study: what to check before relying on this kind of research.

Terms in this paper: Laser, Low-level laser therapy, Visual analogue scale. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies

Oral & Dental

Evaluation of the effectiveness of repeated piezocision versus repeated low-level laser therapy in the acceleration of upper canine retraction in terms of dentoalveolar and periodontal changes: A three-arm randomized controlled clinical trial

While both repeated piezocision and LLLT accelerate upper canine retraction during the initial three months without harming periodontal health, piezocision seems to be more effective than LLLT in speed and time reduction.

Study · November 18, 2026 · Alfailany DT et al.