AI-generated summary
The authors tested whether transcranial laser therapy, using an 808 nm laser, could reverse chronic cognitive and PTSD-related behavioral changes in rats exposed to repeated low-level blasts. Blast-exposed rats received active or sham treatment for six weeks, then were tested on several behavioral tasks. The authors report that the laser therapy did not improve blast-related effects on any test, and that blast-exposed rats were worse after treatment on some anxiety measures.
- Who or what was studied
- Rats exposed to repetitive low-level blast or sham exposure
- Wavelengths
- 808 nm
- Limits stated in the abstract
- The abstract does not state the number of animals per group beyond sham and blast group sizes, and the study is limited to an animal model.
Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.
Abstract
Many military veterans who experienced blast-related traumatic brain injuries (TBIs) in the conflicts in Iraq and Afghanistan suffer from chronic cognitive and mental health problems, including post-traumatic stress disorder (PTSD). Transcranial laser therapy (TLT) uses low-power lasers emitting light in the far- to near-infrared ranges. Beneficial effects of TLT have been reported in neurological and mental-health-related disorders in humans and animal models, including TBI. Rats exposed to repetitive low-level blast develop chronic cognitive and PTSD-related behavioral traits. We tested whether TLT treatment could reverse these traits. Rats received a 74.5-kPa blast or sham exposures delivered one per day for 3 consecutive days. Beginning at 34 weeks after blast exposure, the following groups of rats were treated with active or sham TLT: 1) Sham-exposed rats (n = 12) were treated with sham TLT; 2) blast-exposed rats (n = 13) were treated with sham TLT; and 3) blast-exposed rats (n = 14) were treated with active TLT. Rats received 5 min of TLT five times per week for 6 weeks (wavelength, 808 nm; power of irradiance, 240 mW). At the end of treatment, rats were tested in tasks found previously to be most informative (novel object recognition, novel object localization, contextual/cued fear conditioning, elevated zero maze, and light/dark emergence). TLT did not improve blast-related effects in any of these tests, and blast-exposed rats were worse after TLT in some anxiety-related measures. Based on these findings, TLT does not appear to be a promising treatment for the chronic cognitive and mental health problems that follow blast injury.
Abstract reproduced under the CC BY license. Source: PubMed, a service of the National Library of Medicine.
Light parameters mentioned
Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.
- Wavelength
- 808 nm
- Power
- 240 mW
How to read a single study: what to check before relying on this kind of research.
Terms in this paper: Post-traumatic stress disorder, Laser, Sham, Traumatic brain injury, Near-infrared, Irradiance, Wavelength, Anxiety. Each links to its definition in the glossary.
A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.