Treatment of telangiectasia on the cheeks with a compact yellow (585 nm) semiconductor laser and a green (532 nm) KTP laser: a randomized double-blinded split-face trial

The investigational PhotoLase laser enables significantly faster treatments, but the process is somewhat more painful than with KTP, otherwise providing a similar clinical outcome in the treatment of facial telangiectasia.

Excerpt from the paper’s abstract. Read the full paper for the details.

AI-generated summary

The authors compared an investigational 585 nm yellow laser (PhotoLase) with a 532 nm green KTP laser for facial telangiectasia in a randomized split-face trial with blinded assessors. They report similar improvement by blinded physicians, a higher pain score with PhotoLase, and treatments that were faster. Results were mixed by assessor type, and the abstract does not state a sample size beyond 18 subjects in the outcome figures.

Who or what was studied
Adults with facial telangiectasia (18 subjects reported in the results)
Wavelengths
585, 532 nm
Limits stated in the abstract
The abstract reports a small number of subjects (18) and mixed outcomes, with the PhotoLase laser described as investigational.

Written by an AI model from this paper’s abstract only and checked automatically against it, but it can still be wrong. It is not medical advice. Read the full paper. See the editorial policy.

Abstract

The full abstract is not shown here because it is protected by the publisher’s copyright. Read it on onlinelibrary.wiley.com.

Record from PubMed, a service of the National Library of Medicine.

Light parameters mentioned

Found in the title and abstract by pattern. They may be incomplete, so check the paper before comparing studies.

Wavelength
585 nm, 532 nm

How to read a trial: what to check before relying on this kind of research.

Terms in this paper: Laser, Visual analogue scale. Each links to its definition in the glossary.

A summary of published research, not medical advice. One study rarely settles a question. See the disclaimer and how to read research.

Related studies

Devices & Dosimetry

Fractional non ablative 675 nm diode laser versus low fluence high frequency Q- switched 1064 nm nd: YAG laser in the treatment of melasma: a comparative split face trial

Adverse events were mild and transient. Fractional non-ablative 675 nm diode laser is more effective and equally safe compared to Q-switched 1064 nm Nd:YAG laser in treating facial melasma, offering a promising modality for patients with recalcitrant hyperpigmentation.

Trial · October 15, 2025 · Bassiony HM et al.